Literature DB >> 907460

Cardiac output and pulmonary wedge pressure. Use for evaluation of fluid replacement in trauma patients.

D M Shah, B D Browner, R E Dutton, J C Newell, S R Powers.   

Abstract

Cardiac output and pulmonary wedge pressure (PWP) were used to evaluate the end point of fluid resuscitation in 20 patients suffering from multiple trauma and shock. Eleven patients received crystalloid resuscitation and nine patients received colloid resuscitation. Fifteen of 20 patients had an adequate cardiac output at the termination of resuscitation, but but only six of these patients had a PWP above 10 mm Hg. There was no significant correlation between left ventricular stroke work index and PWP in these patients, either at the completion of resuscitation or during the following three days. Five patients did not achieve adequate cardiac output and four of these patients died, suggesting that cardiac output was the most important criterion for adequate resuscitation. If the goal of fluid resuscitation is to achieve an adequate cardiac output, then PWP was not a reliable guide. Furthermore, using both cardiac output and PWP as a guide to fluid resuscitation of our patients, we found that the type of fluid (crystalloid or colloid) for resuscitation did not influence the course of respiratory distress in these patients up to three days following resuscitation.

Entities:  

Mesh:

Year:  1977        PMID: 907460     DOI: 10.1001/archsurg.1977.01370100015001

Source DB:  PubMed          Journal:  Arch Surg        ISSN: 0004-0010


  7 in total

Review 1.  Human albumin solution for resuscitation and volume expansion in critically ill patients.

Authors:  Ian Roberts; Karen Blackhall; Phil Alderson; Frances Bunn; Gillian Schierhout
Journal:  Cochrane Database Syst Rev       Date:  2011-11-09

2.  Saline resuscitation after fixed-volume hemorrhage. Role of resuscitation volume and rate of infusion.

Authors:  M P Lilly; G J Gala; D E Carlson; B E Sutherland; D S Gann
Journal:  Ann Surg       Date:  1992-08       Impact factor: 12.969

3.  Human albumin administration in critically ill patients: systematic review of randomised controlled trials.

Authors: 
Journal:  BMJ       Date:  1998-07-25

Review 4.  The appropriate role of colloids in managing fluid imbalance: a critical review of recent meta-analytic findings.

Authors:  A R Webb
Journal:  Crit Care       Date:  2000-10-13       Impact factor: 9.097

5.  Colloids versus crystalloids for fluid resuscitation in critically ill people.

Authors:  Sharon R Lewis; Michael W Pritchard; David Jw Evans; Andrew R Butler; Phil Alderson; Andrew F Smith; Ian Roberts
Journal:  Cochrane Database Syst Rev       Date:  2018-08-03

Review 6.  Small-volume resuscitation with hyperoncotic albumin: a systematic review of randomized clinical trials.

Authors:  Matthias Jacob; Daniel Chappell; Peter Conzen; Mahlon M Wilkes; Bernhard F Becker; Markus Rehm
Journal:  Crit Care       Date:  2008-03-04       Impact factor: 9.097

7.  Fluid resuscitation in critically ill patients: a systematic review and network meta-analysis.

Authors:  Chao Liu; Zhi Mao; Pan Hu; Xin Hu; Hongjun Kang; Jie Hu; Zhifang Yang; Penglin Ma; Feihu Zhou
Journal:  Ther Clin Risk Manag       Date:  2018-09-12       Impact factor: 2.423

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.