Literature DB >> 9072098

[CT volumetry of the liver before transplantation].

A J Lemke1, N Hosten, K Neumann, B Müller, P Neuhaus, R Felix, R Langer.   

Abstract

PURPOSE: Purpose of the study was to assess the predictive accuracy of preoperative CT volumetry for water displacement volume after liver transplantation.
METHODS: In a retrospective study the liver volume of 52 patients who underwent an orthotopic liver transplantation, was calculated preoperatively based on incremental and spiral computed tomography (CT). The calculated values were compared with the liver volume measured by water displacement and weight of the extirpated liver.
RESULTS: Marked differences of 19-21.5% were seen between calculated CT volume and water displacement volume for the entire group, and of 12.4-16.9% for livers with a plausible physical liver density (0.9 and 1.1 g/cm3). In this group, 68-86% of the livers were in the acceptable tolerance range for a predictive accuracy (+10% to -20%). Other error sources, such as the breathing shift of the abdominal organs and interobserver variability (1.5-2.7%), were of minor importance for volume calculation.
CONCLUSION: In conclusion, both incremental CT and spiral CT are reliable methods for the preoperative estimation of the liver volume, whereas best accordance with the corrected water displacement volume was obtained using the individual segmentation thresholds.

Entities:  

Mesh:

Year:  1997        PMID: 9072098     DOI: 10.1055/s-2007-1015371

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  8 in total

1.  Preoperative volume calculation of the hepatic venous draining areas with multi-detector row CT in adult living donor liver transplantation: Impact on surgical procedure.

Authors:  Bernd B J Frericks; Timm D Kirchhoff; Hoen-Oh Shin; Georg Stamm; Sonja Merkesdal; Takehiko Abe; Andrea Schenk; Heinz-Otto Peitgen; Jürgen Klempnauer; Michael Galanski; Bjoern Nashan
Journal:  Eur Radiol       Date:  2006-05-19       Impact factor: 5.315

2.  Usage of 64-detector-row spiral computed tomography volumetry in preoperative volume prediction in living donor liver transplantation in children.

Authors:  Ying-Cun Li; Yan Hu; Ming-Man Zhang; Xian-Qing Jin; Xiao Fan; Cong-Lun Pu; Chun-Bao Guo; Quan Kang; Xiao-Ke Dai; Yu-Hua Deng
Journal:  Pediatr Surg Int       Date:  2011-05       Impact factor: 1.827

3.  Liver volume measurement: reason of the difference between in vivo CT-volumetry and intraoperative ex vivo determination and how to cope it.

Authors:  Stefan M Niehues; J K Unger; M Malinowski; J Neymeyer; B Hamm; M Stockmann
Journal:  Eur J Med Res       Date:  2010-08-20       Impact factor: 2.175

4.  Correlation between liver volume and liver weight in a cohort with chronic liver disease: a semiautomated CT-volumetry study.

Authors:  Hans Bösmüller; Marius Horger; Florian Hagen; Antonia Mair
Journal:  Quant Imaging Med Surg       Date:  2022-01

5.  The role of hepatobiliary scintigraphy combined with spect/ct in predicting severity of liver failure before major hepatectomy: a single-center pilot study.

Authors:  Matteo Serenari; Chiara Bonatti; Lucia Zanoni; Giuliano Peta; Elena Tabacchi; Alessandro Cucchetti; Matteo Ravaioli; Cinzia Pettinato; Alberto Bagni; Antonio Siniscalchi; Antonietta D'Errico; Rita Golfieri; Stefano Fanti; Matteo Cescon
Journal:  Updates Surg       Date:  2020-11-02

6.  Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels.

Authors:  Florian Hagen; Antonia Mair; Michael Bitzer; Hans Bösmüller; Marius Horger
Journal:  PLoS One       Date:  2021-08-02       Impact factor: 3.240

7.  Accuracy of preoperative CT liver volumetry in living donor hepatectomy and its clinical implications.

Authors:  Sanjay Goja; Sanjay Kumar Yadav; Amardeep Yadav; Tarun Piplani; Amit Rastogi; Prashant Bhangui; Sanjiv Saigal; Arvinder Singh Soin
Journal:  Hepatobiliary Surg Nutr       Date:  2018-06       Impact factor: 7.293

8.  Sonographic Bedside Quantification of Pleural Effusion Compared to Computed Tomography Volumetry in ICU Patients.

Authors:  Ulf Karl-Martin Teichgräber; Judith Hackbarth
Journal:  Ultrasound Int Open       Date:  2018-10-26
  8 in total