Literature DB >> 9070998

17O-decoupled 1H detection using a double-tuned coil.

R Reddy1, A H Stolpen, S R Charagundla, E K Insko, J S Leigh.   

Abstract

17O-decoupled proton MR spectroscopy imaging with a double-tuned radiofrequency (RF) coil at 2 T was used to detect and quantify H2 17O in tissue containing various concentrations of 17O-enriched water in 5% gelatin. The pulse sequence used in these experiments consisted of a conventional proton spin-echo sequence with RF irradiation at the 17O resonance frequency applied between the proton 90 degrees pulse and the signal acquisition window. The double-tuned coil provided several advantages over systems using separate RF coils for 17O decoupling and proton excitation/detection, including ensuring that the same (or similar) sample volumes are excited and decoupled and permitting accurate calibration of the 17O decoupling pulse amplitude. The efficiency of 17O decoupling as a function of decoupling RF amplitude, decoupling duration, and decoupling resonance offset was investigated. Finally, the specific absorption rate of the 17O decoupled pulse sequence was investigated and found to lie within federal guidelines at 1.5 T.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9070998     DOI: 10.1016/s0730-725x(96)00227-5

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  6 in total

Review 1.  In vivo oxygen-17 NMR for imaging brain oxygen metabolism at high field.

Authors:  Xiao-Hong Zhu; Wei Chen
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2011-04-23       Impact factor: 9.795

2.  Estimation of the regional cerebral metabolic rate of oxygen consumption with proton detected 17O MRI during precision 17O2 inhalation in swine.

Authors:  Eric A Mellon; R Shashank Beesam; James E Baumgardner; Arijitt Borthakur; Walter R Witschey; Ravinder Reddy
Journal:  J Neurosci Methods       Date:  2009-01-20       Impact factor: 2.390

3.  Imaging of H217O distribution in the brain of a live rat by using proton-detected 17O MRI.

Authors:  I Ronen; H Merkle; K Ugurbil; G Navon
Journal:  Proc Natl Acad Sci U S A       Date:  1998-10-27       Impact factor: 11.205

Review 4.  Advanced In Vivo Heteronuclear MRS Approaches for Studying Brain Bioenergetics Driven by Mitochondria.

Authors:  Xiao-Hong Zhu; Fei Du; Nanyin Zhang; Yi Zhang; Hao Lei; Xiaoliang Zhang; Hongyan Qiao; Kamil Ugurbil; Wei Chen
Journal:  Methods Mol Biol       Date:  2009

Review 5.  Quantitative imaging of brain energy metabolisms and neuroenergetics using in vivo X-nuclear 2H, 17O and 31P MRS at ultra-high field.

Authors:  Xiao-Hong Zhu; Ming Lu; Wei Chen
Journal:  J Magn Reson       Date:  2018-07       Impact factor: 2.229

6.  In vivo X-Nuclear MRS Imaging Methods for Quantitative Assessment of Neuroenergetic Biomarkers in Studying Brain Function and Aging.

Authors:  Xiao-Hong Zhu; Wei Chen
Journal:  Front Aging Neurosci       Date:  2018-11-27       Impact factor: 5.750

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.