Application of isotope-selective nondispersive infrared spectrometry (IRIS) for evaluation of [13C]octanoic acid gastric-emptying breath tests: comparison with isotope ratio-mass spectrometry (IRMS).

P Schadewaldt1, B Schommartz, G Wienrich, H Brösicke, R Piolot, D Ziegler.   

Abstract

Suitability of isotope-selective nondispersive infrared spectrometry (IRIS) for evaluation of [13C]octanoic acid gastric-emptying breath test was assessed and compared with standard isotope ratio-mass spectrometry (IRMS). The estimated bias of IRMS and IRIS measurements of baseline-corrected 13CO2 exhalation amounted to +/-0.1 and +/-0.6 delta delta values (n = 360), respectively. In breath tests performed on 60 diabetic patients, the gastric emptying parameters were calculated by nonlinear regression analysis of the time course of 13CO2 exhalation: half-emptying time (t1/2,breath, 90 +/- 39 min), lag phase (tlag,breath, 34 +/- 27 min), and gastric emptying coefficient (GEC, 2.9 +/- 0.5). A reasonable linear correlation was found between the two methods (y = IRIS, x = IRMS) with respect to delta delta values (y = 0.35 + 0.92x, r = 0.985, Sy[symbol: see text]x = +/-0.6, n = 1116) and a rather good agreement of the computed gastric emptying parameters was obtained (t1/2,breath: y = 0.99x + 4.06, Sy[symbol: see text]x = +/- 6.3; tlag, breath: y = 0.97x + 0.96, Sy[symbol: see text]x = +/-3.4; GEC: y = 0.97x - 0.01, Sy[symbol: see text]x = +/-0.09).

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9068597

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  7 in total

1.  Time-course of recovery of gastric emptying and motility in rats with experimental spinal cord injury.

Authors:  E Qualls-Creekmore; M Tong; G M Holmes
Journal:  Neurogastroenterol Motil       Date:  2009-06-30       Impact factor: 3.598

2.  [13C]glucose breath testing provides a noninvasive measure of insulin resistance: calibration analyses against clamp studies.

Authors:  Maysa Hussain; Morteza Jangorbhani; Sally Schuette; Robert V Considine; Robin L Chisholm; Kieren J Mather
Journal:  Diabetes Technol Ther       Date:  2013-10-11       Impact factor: 6.118

3.  Short- and medium-term reproducibility of gastric emptying of a solid meal determined by a low dose of 13C-octanoic acid and nondispersive isotope-selective infrared spectrometry.

Authors:  Anna Kasicka-Jonderko; Magdalena Kamińska; Krzysztof Jonderko; Olga Setera; Barbara Błońska-Fajfrowska
Journal:  World J Gastroenterol       Date:  2006-02-28       Impact factor: 5.742

4.  Clinical experience of use of 13C-breath tests in oesophagogastroduodenal diseases: selective questions.

Authors:  Vadim Shypulin; Volodimir Chernyavskyi; Tetyana Nechypurenko; Artyom Neverovskyi; Lesya Gvozdecka; Natallya Mikhn'ova
Journal:  Prz Gastroenterol       Date:  2019-12-01

Review 5.  European guideline on indications, performance and clinical impact of 13 C-breath tests in adult and pediatric patients: An EAGEN, ESNM, and ESPGHAN consensus, supported by EPC.

Authors:  Jutta Keller; Heinz F Hammer; Paul R Afolabi; Marc Benninga; Osvaldo Borrelli; Enrique Dominguez-Munoz; Dan Dumitrascu; Oliver Goetze; Stephan L Haas; Bruno Hauser; Daniel Pohl; Silvia Salvatore; Marc Sonyi; Nikhil Thapar; Kristin Verbeke; Mark R Fox
Journal:  United European Gastroenterol J       Date:  2021-06-14       Impact factor: 4.623

6.  Traditional Malian Solid Foods Made from Sorghum and Millet Have Markedly Slower Gastric Emptying than Rice, Potato, or Pasta.

Authors:  Fatimata Cisse; Daniel P Erickson; Anna M R Hayes; Antone R Opekun; Buford L Nichols; Bruce R Hamaker
Journal:  Nutrients       Date:  2018-01-26       Impact factor: 5.717

Review 7.  Understanding the role of the gut in undernutrition: what can technology tell us?

Authors:  Alex J Thompson; Claire D Bourke; Ruairi C Robertson; Nirupama Shivakumar; Christine A Edwards; Tom Preston; Elaine Holmes; Paul Kelly; Gary Frost; Douglas J Morrison
Journal:  Gut       Date:  2021-06-08       Impact factor: 23.059

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.