Literature DB >> 906555

Clinical results of real-time ultrasonic scanning of the heart using a phased array system.

J A Kisslo, O T vonRamm, F L Thurstone.   

Abstract

This report describes the operating characteristics and initial clinical results of a new echocardiographic system that produces real-time, high resolution, cross-sectional images of the heart. This system relies upon phased-array principles to rapidly steer and focus the ultrasound beam through the cardiac structures under investigation. A hand-held, linear array of 24 transducers is manipulated on the patient's chest to direct the interrogating plane at various cardiac structures. Images of high line density are presented in selectable sector arcs to a maximum of 90 degrees. This imaging system has been used clinically in over 2,000 patients in the past two and one-half years. Its use in the detection of altered states of ventricular and valvular pathology has been described.

Entities:  

Mesh:

Year:  1977        PMID: 906555      PMCID: PMC2595525     

Source DB:  PubMed          Journal:  Yale J Biol Med        ISSN: 0044-0086


  6 in total

1.  Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application.

Authors:  J Kisslo; O T vonRamm; F L Thurstone
Journal:  Circulation       Date:  1976-02       Impact factor: 29.690

2.  Cardiac imaging using a phased array ultrasound system. I. System design.

Authors:  O T vonRamm; F L Thurstone
Journal:  Circulation       Date:  1976-02       Impact factor: 29.690

3.  A comparison of real-time, two dimensional echocardiography and cineangiography in detecting left ventricular asynergy.

Authors:  J A Kisslo; D Robertson; B W Gilbert; O von Ramm; V S Behar
Journal:  Circulation       Date:  1977-01       Impact factor: 29.690

4.  Two-dimensional echocardiographic assessment of mitral stenosis.

Authors:  P M Nichol; B W Gilbert; J A Kisslo
Journal:  Circulation       Date:  1977-01       Impact factor: 29.690

5.  Echocardiographic evaluation of tricuspid valve endocarditis: an M mode and two dimensional study.

Authors:  J Kisslo; O T Von Ramm; R Haney; R Jones; S S Juk; V S Behar
Journal:  Am J Cardiol       Date:  1976-10       Impact factor: 2.778

6.  Mitral valve prolapse. Two-dimensional echocardiographic and angiographic correlation.

Authors:  B W Gilbert; R A Schatz; O T VonRamm; V S Behar; J A Kisslo
Journal:  Circulation       Date:  1976-11       Impact factor: 29.690

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.