Literature DB >> 9063850

Compound osteosynthesis of pathological fractures of the proximal femoral shaft. Experimental studies on the biomechanical effects of additional intramedullary splinting.

K D Heller1, K W Zilkens, B Cohen, J Hammer.   

Abstract

The biomechanical stability of two compound osteosynthesis techniques with and without intramedullary splinting were compared in 20 paired cadaver femora. Group A was stabilised using a contoured 12-hole DC plate and polymethylmethacrylate cement. In group B an additional intramedullary semi-diameter osteosynthesis plate was inserted parallel to the outer plate and transfixed with the same screws. The specimens were tested in a universal testing machine using a force applied to the specimen at 45 degrees to the load to provoke the most unfavourable condition, consisting of a bending moment and torsion. Both force and extension were recorded. The compound osteosynthesis with an additional intramedullary plate (group B) reached an average higher load stability. This increase of stability was not significant statistically.

Entities:  

Mesh:

Year:  1996        PMID: 9063850     DOI: 10.1007/bf00573454

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  8 in total

1.  Anchorage of the femoral head prosthesis to the shaft of the femur.

Authors:  J CHARNLEY
Journal:  J Bone Joint Surg Br       Date:  1960-02

2.  Experimental stabilization of segmental defects in the human femur. A torsional study.

Authors:  J S Mensch; K L Markolf; S B Roberts; G M Finerman
Journal:  J Bone Joint Surg Am       Date:  1976-03       Impact factor: 5.284

3.  Strength reduction and the effects of treatment of long bones with diaphyseal defects involving 50% of the cortex.

Authors:  R E Leggon; R W Lindsey; M M Panjabi
Journal:  J Orthop Res       Date:  1988       Impact factor: 3.494

4.  The fixation of experimental femoral shaft torque fractures.

Authors:  M J Hubbard
Journal:  Acta Orthop Scand       Date:  1973

5.  [Surgical technic in femur shaft fenestration within the scope of revision operations following hip joint total endoprostheses].

Authors:  E Savvidis; F Löer
Journal:  Z Orthop Ihre Grenzgeb       Date:  1989 Mar-Apr

6.  Pathologic femoral shaft fractures comparing fixation techniques using cement.

Authors:  J T Anderson; J M Erickson; R C Thompson; E Y Chao
Journal:  Clin Orthop Relat Res       Date:  1978 Mar-Apr       Impact factor: 4.176

7.  Performance evaluation of a cement-augmented intramedullary fixation system for pathologic lesions of the femoral shaft.

Authors:  G J Miller; R A Vander Griend; W P Blake; D S Springfield
Journal:  Clin Orthop Relat Res       Date:  1987-08       Impact factor: 4.176

8.  Internal fixation technique in pathological fractures of the extremities.

Authors:  R Ganz; B Isler; J Mast
Journal:  Arch Orthop Trauma Surg       Date:  1984
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.