Literature DB >> 9059095

Effect of the size of a tracheal tube and the efficacy of the use of the laryngeal mask for fibrescope-aided tracheal intubation.

K Koga1, T Asai, I P Latto, R S Vaughan.   

Abstract

We randomly allocated 60 patients with normal airways into three groups to compare the ease of fibrescope-aided tracheal intubation using 8.0-mm internal diameter (group F8) and 6.0-mm (group F6) reinforced tracheal tubes and to evaluate the efficacy of the laryngeal mask as an aid for fibreoptic tracheal intubation (group L). In group F8 tracheal intubation was optimal in 2 of 20 patients and in two patients in whom intubation over the fibrescope was difficult the attempts resulted in inadvertent oesophageal intubation. In group F6 intubation was always successful and significantly easier than in group F8 (p < 0.005; 95% confidence interval for the difference in the proportion of the optimal intubation grade: 20-70%). In group L tracheal intubation was optimal in 18 of 20 patients and easier than in group F6 (p = 0.014; 95% confidence interval for difference: 10-60%). In both groups F6 and L tracheal intubation was completed within less than about 1 min. We conclude that conventional fibrescope-aided tracheal intubation with a 6.0-mm tracheal tube is easier than with an 8.0-mm tube and that the laryngeal mask facilitates fibrescope-aided tracheal intubation.

Entities:  

Mesh:

Year:  1997        PMID: 9059095     DOI: 10.1111/j.1365-2044.1997.31-az0058.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  6 in total

1.  [Intubation with a tube exchanger on an intubation trainer. Influence of tube tip position on successful intubation].

Authors:  M Kemper; T Haas; S Imach; M Weiss
Journal:  Anaesthesist       Date:  2014-07-02       Impact factor: 1.041

2.  Patient factors associated with difficult flexible bronchoscopic intubation under general anesthesia: a prospective observational study.

Authors:  Taher Touré; Stephan R Williams; Mahmoud Kerouch; Monique Ruel
Journal:  Can J Anaesth       Date:  2020-01-17       Impact factor: 5.063

3.  Comparison of hemodynamic responses to intubation: Flexible fiberoptic bronchoscope versus McCoy laryngoscope in presence of rigid cervical collar simulating cervical immobilization for traumatic cervical spine.

Authors:  Nitesh Gill; Shobha Purohit; Poonam Kalra; Tarun Lall; Avneesh Khare
Journal:  Anesth Essays Res       Date:  2015 Sep-Dec

4.  Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adults.

Authors:  I Ahmad; K El-Boghdadly; R Bhagrath; I Hodzovic; A F McNarry; F Mir; E P O'Sullivan; A Patel; M Stacey; D Vaughan
Journal:  Anaesthesia       Date:  2019-11-14       Impact factor: 6.955

5.  Effects of bevel direction of endotracheal tube on the postoperative sore throat when performing fiberoptic-guided tracheal intubation: A randomized controlled trial.

Authors:  Hyunjee Kim; Jeong Eon Kim; Woo Seok Yang; Seong Wook Hong; Hoon Jung
Journal:  Medicine (Baltimore)       Date:  2022-09-02       Impact factor: 1.817

6.  A cohort evaluation of clinical use and performance characteristics of Ambu® AuraGain™: A prospective observational study.

Authors:  Devangi A Parikh; Ruchi A Jain; Smita S Lele; Bharati A Tendolkar
Journal:  Indian J Anaesth       Date:  2017-08
  6 in total