Literature DB >> 9057521

Detection and segmental location of malignant hepatic tumors: comparison of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging.

B E Van Beers1, M Lacrosse, J Jamart, C Grandin, J F Gigot, Y Horsmans, R Demeure, J Pringot.   

Abstract

OBJECTIVE: The aim of our prospective study was to compare the values of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging for the detection and segmental location of malignant hepatic tumors. SUBJECTS AND METHODS: Eighteen patients underwent ferumoxides-enhanced T2 weighted spin-echo and steady-state gradient-echo imaging before surgery. Intraoperative sonography was used as the reference examination and showed 28 malignant tumors involving 39 of the 144 hepatic segments. The MR images were reviewed independently by two observers who recorded the number of tumors and their segmental location. The results of the segmental location were subjected to receiver-operating-characteristic analysis. Tumor-liver, vessel-liver, and tumor-vessel contrast-to-noise ratios were calculated.
RESULTS: Detection on the gradient-echo images did not differ significantly from that on the T2-weighted spin-echo MR images (observers A and B detected 23 and 24 tumors, respectively, on the gradient-echo images; the two observers each detected 22 tumors on the T2-weighted spin-echo images). Segmental localization was significantly better on the gradient-echo images than on the T2-weighted spin-echo images (mean area under the receiver-operating-characteristic curve: 0.974 versus 0.895 for observer A and 0.962 versus 0.906 for observer B, p = .024). The highest contrast-to-noise ratios for vessel to liver and tumor to vessel were obtained on the gradient-echo images and the highest tumor-liver contrast-to-noise ratio was obtained on the T2-weighted spin-echo images.
CONCLUSION: In our study, ferumoxides-enhanced gradient-echo imaging was as accurate as T2-weighted spin-echo imaging for revealing malignant hepatic tumors and was superior for showing their segmental location.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9057521     DOI: 10.2214/ajr.168.3.9057521

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

1.  Diagnostic performance of MDCT, PET/CT and gadoxetic acid (Primovist(®))-enhanced MRI in patients with colorectal liver metastases being considered for hepatic resection: initial experience in a single centre.

Authors:  V O Chan; J P Das; J F Gerstenmaier; J Geoghegan; R G Gibney; C D Collins; S J Skehan; D E Malone
Journal:  Ir J Med Sci       Date:  2012-03-17       Impact factor: 1.568

Review 2.  Cost-effectiveness of hepatic metastasectomy in patients with metastatic colorectal carcinoma: a state-transition Monte Carlo decision analysis.

Authors:  G Scott Gazelle; M G Myriam Hunink; Karen M Kuntz; Pamela M McMahon; Elkan F Halpern; Molly Beinfeld; Jessica S Lester; Kenneth K Tanabe; Milton C Weinstein
Journal:  Ann Surg       Date:  2003-04       Impact factor: 12.969

3.  Optimal pulse sequence for ferumoxides-enhanced MR imaging used in the detection of hepatocellular carcinoma: a comparative study using seven pulse sequences.

Authors:  Seung Hoon Kim; Dongil Choi; Jae Hoon Lim; Won Jae Lee; Hyun Jung Jang; Hyo Keun Lim; Soon Jin Lee; Jae Min Cho; Seung Kwon Kim; Gab Chul Kim
Journal:  Korean J Radiol       Date:  2002 Apr-Jun       Impact factor: 3.500

4.  Small malignant hepatic tumor detection in gadolinium- and ferucarbotran-enhanced magnetic resonance imaging: does combining ferucarbotran-enhanced T2*-weighted gradient echo and T2-weighted turbo spin echo images have additive efficacy?

Authors:  Young Kon Kim; Young Hwan Lee; Hyo Sung Kwak; Chong Soo Kim; Young Min Han
Journal:  Korean J Radiol       Date:  2008 Nov-Dec       Impact factor: 3.500

  4 in total