Charge and Size Distributions of Electrospray Drops

.   

Abstract

The distributions of charge q and diameter d of drops emitted from electrified liquid cones in the cone-jet mode are investigated with two aerosol instruments. A differential mobility analyzer (DMA, Vienna type) first samples the spray drops, selects those with electrical mobilities within a narrow band, and either measures the associated current or passes them to a second instrument. The drops may also be individually counted optically and sized by sampling them into an aerodynamic size spectrometer (API's Aerosizer). For a given cone-jet, the distribution of charge q for the main electrospray drops is some 2.5 times broader than their distribution of diameters d, with qmax/qmin approximately 4. But mobility-selected drops have relative standard deviations of only 5% for both d and q, showing that the support of the (q, d) distribution is a narrow band centered around a curve q(d). The approximate one-dimensionality of this support region is explained through the mechanism of jet breakup, which is a random process with only one degree of freedom: the wavelength of axial modulation of the jet. The observed near constancy of the charge over volume ratio (q approximately d3) shows that the charge is frozen in the liquid surface at the time scale of the breakup process. The charge over volume ratio of the primary drops varies between 98 and 55% of the ratio of spray current I over liquid flow rate Q, and decreases at increasing Q. I/Q is therefore an unreliable measure of the charge density of these drops.

Year:  1997        PMID: 9056353     DOI: 10.1006/jcis.1996.4654

Source DB:  PubMed          Journal:  J Colloid Interface Sci        ISSN: 0021-9797            Impact factor:   8.128


  13 in total

1.  Automated orthogonal control system for electrospray ionization.

Authors:  Gary A Valaskovic; James P Murphy; Mike S Lee
Journal:  J Am Soc Mass Spectrom       Date:  2004-08       Impact factor: 3.109

2.  A study of electrospray ionization emitters with differing geometries with respect to flow rate and electrospray voltage.

Authors:  Brent R Reschke; Aaron T Timperman
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-12       Impact factor: 3.109

3.  Generating Charged Pharmaceutical Aerosols Intended to Improve Targeted Drug Delivery in Ventilated Infants.

Authors:  Landon Holbrook; Michael Hindle; P Worth Longest
Journal:  J Aerosol Sci       Date:  2015-10-01       Impact factor: 3.433

4.  Estimates of protein surface areas in solution by electrospray ionization mass spectrometry.

Authors:  Igor A Kaltashov; Anirban Mohimen
Journal:  Anal Chem       Date:  2005-08-15       Impact factor: 6.986

5.  Current-controlled nanospray ionization mass spectrometry.

Authors:  Alexei Gapeev; Alberto Berton; Daniele Fabris
Journal:  J Am Soc Mass Spectrom       Date:  2009-03-14       Impact factor: 3.109

6.  Hydrogen/deuterium exchange of hydrophobic peptides in model membranes by electrospray ionization mass spectrometry.

Authors:  Raino K Hansen; R William Broadhurst; Paul C Skelton; Isaiah T Arkin
Journal:  J Am Soc Mass Spectrom       Date:  2002-12       Impact factor: 3.109

7.  A chemical free, nanotechnology-based method for airborne bacterial inactivation using engineered water nanostructures.

Authors:  Georgios Pyrgiotakis; James McDevitt; Andre Bordini; Edgar Diaz; Ramon Molina; Christa Watson; Glen Deloid; Steve Lenard; Natalie Fix; Yosuke Mizuyama; Toshiyuki Yamauchi; Joseph Brain; Philip Demokritou
Journal:  Environ Sci Nano       Date:  2014

8.  Dramatic Improvement in Sensitivity with Pulsed Mode Charge Detection Mass Spectrometry.

Authors:  Aaron R Todd; Martin F Jarrold
Journal:  Anal Chem       Date:  2019-10-07       Impact factor: 6.986

9.  Monte carlo simulation of macromolecular ionization by nanoelectrospray.

Authors:  Christopher J Hogan; Pratim Biswas
Journal:  J Am Soc Mass Spectrom       Date:  2008-05-16       Impact factor: 3.109

10.  Gas sensors based on electrospun nanofibers.

Authors:  Bin Ding; Moran Wang; Jianyong Yu; Gang Sun
Journal:  Sensors (Basel)       Date:  2009-03-09       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.