Literature DB >> 9056218

Absolute molecular weight distribution of low-molecular-weight heparins by size-exclusion chromatography with multiangle laser light scattering detection.

J E Knobloch1, P N Shaklee.   

Abstract

The absolute molecular weight (M(r)) distribution of seven low-molecular-weight (LMW) heparin products was determined by size-exclusion chromatography (SEC) coupled with multiangle laser light scattering (MALLS) detection. The SEC/MALLS technique does not rely on relative M(r) standards for column calibration and yields absolute M(r) estimates directly from the angular dependence of scattered light intensity as a function of concentration, as formulated by light scattering theory. The SEC/MALLS method we describe is rapid, precise, and accurate. In 1 h it yields results from triplicate injections that agree well with the manufacturers' own independent analyses and that exhibit coefficients of variation of approximately 1%. By eliminating the requirement for finite quantities of highly purified, well-characterized M(r) standards derived from heparin, the present procedure represents a clear improvement over relative methods of M(r) determination. Thus, it is concluded that the SEC/MALLS method is ideally suited to routine quality control of commercial LMW-heparin products.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9056218     DOI: 10.1006/abio.1996.9984

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  7 in total

1.  Conformation of heparin studied with macromolecular hydrodynamic methods and X-ray scattering.

Authors:  Georges Pavlov; Stéphanie Finet; Karine Tatarenko; Evgueniya Korneeva; Christine Ebel
Journal:  Eur Biophys J       Date:  2003-07-03       Impact factor: 1.733

2.  Refractive index-based determination of detergent concentration and its application to the study of membrane proteins.

Authors:  Pavel Strop; Axel T Brunger
Journal:  Protein Sci       Date:  2005-08       Impact factor: 6.725

3.  Parallel chromatography and in situ scattering to interrogate competing protein aggregation pathways.

Authors:  Diana Gomes; Rebecca K Kalman; Rebecca K Pagels; Miguel A Rodrigues; Christopher J Roberts
Journal:  Protein Sci       Date:  2018-06-13       Impact factor: 6.725

4.  Structure of a myosin•adaptor complex and pairing by cargo.

Authors:  Hang Shi; Nimisha Singh; Filipp Esselborn; Günter Blobel
Journal:  Proc Natl Acad Sci U S A       Date:  2014-02-12       Impact factor: 11.205

5.  Size exclusion chromatography-multiangle laser light scattering analysis of hyaluronan size distributions made by membrane-bound hyaluronan synthase.

Authors:  Bruce A Baggenstoss; Paul H Weigel
Journal:  Anal Biochem       Date:  2006-01-31       Impact factor: 3.365

6.  Rational design of low-molecular weight heparins with improved in vivo activity.

Authors:  Mallik Sundaram; Yiwei Qi; Zachary Shriver; Dongfang Liu; Ganlin Zhao; Ganesh Venkataraman; Robert Langer; Ram Sasisekharan
Journal:  Proc Natl Acad Sci U S A       Date:  2003-01-13       Impact factor: 11.205

Review 7.  Tools for the Quality Control of Pharmaceutical Heparin.

Authors:  Anthony Devlin; Courtney Mycroft-West; Patricia Procter; Lynsay Cooper; Scott Guimond; Marcelo Lima; Edwin Yates; Mark Skidmore
Journal:  Medicina (Kaunas)       Date:  2019-09-25       Impact factor: 2.430

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.