Literature DB >> 9056168

Correlations among bone mineral density, broadband ultrasound attenuation, mechanical indentation testing, and bone orientation in bovine femoral neck samples.

J Duquette1, J Lin, A Hoffman, J Houde, S Ahmadi, D Baran.   

Abstract

Broadband ultrasound attenuation (BUA) of the calcaneus has been found to correlate with bone mineral density (BMD) of the femoral neck. The purpose of this study was to determine if a correlation exists among femoral neck BUA, femoral neck BMD, and incremental indent depth, a qualitative indicator of local mechanical bone strength, in bovine samples, and if this correlation is dependent upon orientation. For 12 of the bovine samples obtained, BUA was measured at the femoral neck and was followed by a BMD determination of the same area. A 19 mm diameter bicortical core containing the center of the area of interest was removed, transversely cut into 7 mm, thick disks, and tested for hardness by indent depth. For these tests, BMD was well correlated with BUA (R2 = 0.85, P < 0.001). An inversely proportional relationship with a modest correlation was found between indent depth and BMD (R2 = 0.59, P = 0.026), and indent depth and BUA (R2 = 0.57, P = 0.031). In a second set of tests involving 15 different bovine samples, a bicortical core was removed from the femoral neck. A trabecular bone cube measuring 1.5 cm on a side was removed from the center of the core. BUA and BMD measurements were made along the anterior-posterior (AP), medial-lateral (ML), and cephalic-caudal (CC) aspects of the cube. The cubes were randomly separated into three groups, cut in half perpendicular to the axis of interest, and tested for hardness by indent depth. In these tests, no significant difference was found in BMD among the three orientations of the cubes scanned (P = 0.77). In contrast, the BUA along the ML orientation of the cube was significantly greater than that along the AP orientation (P < 0.05). No significant difference was found in the incremental indent depth measurements among cube orientations (P = 0.41). In the test involving only trabecular bone, a much higher correlation between BMD and incremental indent depth was found regardless of cube orientation (R2 = 0.64, P < 0.001). The data indicate that BUA, but not BMD, is affected by trabecular orientation, and that BMD is negatively correlated with incremental indent depth.

Entities:  

Mesh:

Year:  1997        PMID: 9056168     DOI: 10.1007/s002239900211

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  4 in total

1.  The influence of dairy consumption and physical activity on ultrasound bone measurements in Flemish children.

Authors:  Stephanie De Smet; Nathalie Michels; Carolien Polfliet; Sara D'Haese; Inge Roggen; Stefaan De Henauw; Isabelle Sioen
Journal:  J Bone Miner Metab       Date:  2014-03-15       Impact factor: 2.626

2.  Quantitative ultrasound and fracture risk prediction in non-osteoporotic men and women as defined by WHO criteria.

Authors:  M Y Chan; N D Nguyen; J R Center; J A Eisman; T V Nguyen
Journal:  Osteoporos Int       Date:  2012-08-10       Impact factor: 4.507

3.  Bone mineral density in prepubertal obese and control children: relation to body weight, lean mass, and fat mass.

Authors:  Emilie Rocher; Christine Chappard; Christelle Jaffre; Claude-Laurent Benhamou; Daniel Courteix
Journal:  J Bone Miner Metab       Date:  2008-01-10       Impact factor: 2.626

4.  Straight proximal humeral nails are surrounded by more bone stock in comparison to bent nails in an experimental cadaveric study.

Authors:  Christian Max Günther; Peter Ernst Müller; Wolf Mutschler; Christoph Martin Sprecher; Stefan Milz; Volker Braunstein
Journal:  Patient Saf Surg       Date:  2014-04-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.