Literature DB >> 9052466

High-intensity focused ultrasound in the treatment of benign prostatic hyperplasia.

E D Mulligan1, T H Lynch, D Mulvin, D Greene, J M Smith, J M Fitzpatrick.   

Abstract

OBJECTIVE: To assess the role of high-intensity focused ultrasound (HIFU) in the treatment of symptomatic benign prostatic hyperplasia (BPH). PATIENTS AND METHODS: Thirteen patients (mean age 65 years, range 58-74) were treated with HIFU as part of a phase-2 clinical trial and evaluated prospectively using the International Prostate Symptom Score, uroflowmetry, and transrectal and transabdominal ultrasonography to determine prostate size and post-void residual urine volume, respectively. The results and the patients' satisfaction were assessed at regular intervals for 2 years.
RESULTS: The new procedure was learned quickly and was easy to perform. Symptom scores decreased from a mean of 23 before treatment to 5 after 12 months and 7 after 2 years. There was an initial improvement in flow rates but they then declined. The size of the prostate and the post-void residual volume were both decreased after treatment.
CONCLUSIONS: The treatment is safe, easy to implement and was effective in substantially reducing symptom scores in these few patients. However, we would not encourage its use as an alternative to other well established treatment modalities until it has been assessed fully in a randomized trial.

Entities:  

Mesh:

Year:  1997        PMID: 9052466     DOI: 10.1046/j.1464-410x.1997.03286.x

Source DB:  PubMed          Journal:  Br J Urol        ISSN: 0007-1331


  7 in total

1.  Shape-based ultrasound tomography using a Born model with application to high intensity focused ultrasound therapy.

Authors:  Başak Ulker Karbeyaz; Eric L Miller; Robin O Cleveland
Journal:  J Acoust Soc Am       Date:  2008-05       Impact factor: 1.840

2.  MR-acoustic radiation force imaging (MR-ARFI) and susceptibility weighted imaging (SWI) to visualize calcifications in ex vivo swine brain.

Authors:  Rachel R Bitton; Kim R Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2013-10-10       Impact factor: 4.813

3.  Arterial blood flow occlusion by high intensity focused ultrasound and histologic evaluation of its effect on arteries and surrounding tissues.

Authors:  Rei Fujiwara; Kazuaki Sasaki; Tetsuya Ishikawa; Makoto Suzuki; Shin-Ichiro Umemura; Miki Kushima; Takashi Okai
Journal:  J Med Ultrason (2001)       Date:  2002-09       Impact factor: 1.314

4.  Sequential changes in rat femoral artery blood flow and tissue degeneration after exposure to high-intensity focused ultrasound.

Authors:  Tetsuya Ishikawa; Takashi Okai; Kazuaki Sasaki; Shin-Ichiro Umemura; Nozomi Miyazaki; Miki Kushima; Hiroko Aoki; Mitsuyoshi Ichihara; Kiyotake Ichizuka
Journal:  J Med Ultrason (2001)       Date:  2008-12-16       Impact factor: 1.314

5.  Histopathological changes associated with high intensity focused ultrasound (HIFU) treatment for localised adenocarcinoma of the prostate.

Authors:  G J Van Leenders; H P Beerlage; E T Ruijter; J J de la Rosette; C A van de Kaa
Journal:  J Clin Pathol       Date:  2000-05       Impact factor: 3.411

6.  Against the motion: Lasers are superfluous for the surgical management of benign prostatic hyperplasia in the developing world.

Authors:  Anil Varshney; Anshuman Agarwal
Journal:  Indian J Urol       Date:  2009-07

Review 7.  Sexual function in patients with benign prostatic hyperplasia.

Authors:  P K Hegarty; N J Hegarty; J M Fitzpatrick
Journal:  Curr Urol Rep       Date:  2001-08       Impact factor: 2.862