Rapid objective measurement of gamma camera resolution using statistical moments.

T A Hander1, J L Lancaster, D T Kopp, J C Lasher, R Blumhardt, P T Fox.   

Abstract

An easy and rapid method for the measurement of the intrinsic spatial resolution of a gamma camera was developed. The measurement is based on the first and second statistical moments of regions of interest (ROIs) applied to bar phantom images. This leads to an estimate of the modulation transfer function (MTF) and the full-width-at-half-maximum (FWHM) of a line spread function (LSF). Bar phantom images were acquired using four large field-of-view (LFOV) gamma cameras (Scintronix, Picker, Searle, Siemens). The following factors important for routine measurements of gamma camera resolution with this method were tested: ROI placement and shape, phantom orientation, spatial sampling, and procedural consistency. A 0.2% coefficient of variation (CV) between repeat measurements of MTF was observed for a circular ROI. The CVs of less than 2% were observed for measured MTF values for bar orientations ranging from -10 degrees to +10 degrees with respect to the x and y axes of the camera acquisition matrix. A 256 x 256 matrix (1.6 mm pixel spacing) was judged sufficient for routine measurements, giving an estimate of the FWHM to within 0.1 mm of manufacturer-specified values (3% difference). Under simulated clinical conditions, the variation in measurements attributable to procedural effects yielded a CV of less than 2% in newer generation cameras. The moments method for determining MTF correlated well with a peak-valley method, with an average difference of 0.03 across the range of spatial frequencies tested (0.11-0.17 line pairs/mm, corresponding to 4.5-3.0 mm bars). When compared with the NEMA method for measuring intrinsic spatial resolution, the moments method was found to be within 4% of the expected FWHM.

Entities:  

Mesh:

Year:  1997        PMID: 9048375     DOI: 10.1118/1.597928

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  A proton imaging system using a volumetric liquid scintillator: a preliminary study.

Authors:  Chinmay D Darne; Fahed Alsanea; Daniel G Robertson; Fada Guan; Tinsu Pan; David Grosshans; Sam Beddar
Journal:  Biomed Phys Eng Express       Date:  2019-07-12

2.  Analytical and experimental FWHM of a gamma camera: theoretical and practical issues.

Authors:  Diego Cecchin; Davide Poggiali; Lucia Riccardi; Paolo Turco; Franco Bui; Stefano De Marchi
Journal:  PeerJ       Date:  2015-02-03       Impact factor: 2.984

3.  Observed inter-camera variability of clinically relevant performance characteristics for Siemens Symbia gamma cameras.

Authors:  S Cheenu Kappadath; William D Erwin; Richard E Wendt
Journal:  J Appl Clin Med Phys       Date:  2006-11-28       Impact factor: 2.102

4.  Automated phantom analysis for gamma cameras and SPECT: A methodology for use in a clinical setting.

Authors:  Tutku E Tazegul; Andrew M Polemi; Angela Snyder; Carl Snyder; Patricia G Collins
Journal:  J Appl Clin Med Phys       Date:  2020-11-03       Impact factor: 2.243

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.