Literature DB >> 9046489

Prolonged myocardial contrast echocardiography via peripheral venous administration of QW3600 injection (EchoGen): its efficacy and side effects.

S Beppu1, H Matsuda, T Shishido, M Matsumura, K Miyatake.   

Abstract

We examined the efficacy and side effects of a newly developed contrast agent for intravenous myocardial contrast echocardiography, QW3600 Injection (EchoGen; Sonus Pharmaceuticals, Bothell, Wash.). Doses of 0.1, 0.2, 0.5, and 0.8 ml/kg of this agent were administered intravenously to 8 open-chested dogs. The left ventricular (LV) myocardium was uniformly well opacified for the 0.5 and 0.8 ml/kg doses, for which the peak intensity was an average of 40 gray levels above the baseline intensity. The myocardial opacification persisted even after the contrast echo intensity in the LV cavity had decreased. After ligation of the coronary artery, the area at risk was clearly delineated by the same doses. The agent emulsion and dissolved bubbles were examined microscopically in vitro and in vivo to elucidate the mechanism of prolonged opacification. A microscopic investigation of the mesenteric vessels of a rat indicated that bubbles had formed, growing as large as 30 to 50 microm [corrected] in diameter. The hemodynamic parameters did not change at low doses (0.1 and 0.2 ml/kg), but the systemic pressure fell and the arterial blood oxygen saturation decreased at high doses (0.5 and 0.8 ml/kg). EchoGen provides prolonged contrast for myocardial contrast echocardiography via peripheral venous administration, although the hemodynamic parameters deteriorate at high doses.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9046489     DOI: 10.1016/s0894-7317(97)80028-4

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  5 in total

Review 1.  Added value of contrast echocardiography in assessing myocardial viability.

Authors:  A Nagy; F L Dini; D Rovai
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

Review 2.  New ultrasound contrast agents for left ventricular and myocardial opacification.

Authors:  J D Kasprzak; F J Ten Cate
Journal:  Herz       Date:  1998-12       Impact factor: 1.443

3.  Selective Enhancement of Swine Myocardium with a Novel Ultrasound Enhancing Agent During Transthoracic Echocardiography.

Authors:  Michael Cimorelli; Michael A Flynn; Brett Angel; Emily Reimold; Sahil S Banka; Benjamin Andrien; Aaron Fafarman; Richard Huneke; Andrew Kohut; Steven Wrenn
Journal:  J Cardiovasc Transl Res       Date:  2022-01-31       Impact factor: 3.216

4.  Carbon monoxide inhalation increases microparticles causing vascular and CNS dysfunction.

Authors:  Jiajun Xu; Ming Yang; Paul Kosterin; Brian M Salzberg; Tatyana N Milovanova; Veena M Bhopale; Stephen R Thom
Journal:  Toxicol Appl Pharmacol       Date:  2013-09-30       Impact factor: 4.219

5.  Microparticles Impair Hypotensive Cerebrovasodilation and Cause Hippocampal Neuronal Cell Injury after Traumatic Brain Injury.

Authors:  Leif-Erik Bohman; John Riley; Tatyana N Milovanova; Matthew R Sanborn; Stephen R Thom; William M Armstead
Journal:  J Neurotrauma       Date:  2015-07-31       Impact factor: 5.269

  5 in total