Literature DB >> 9046488

Harmonic imaging with Levovist.

K Q Schwarz1, X Chen, S Steinmetz, D Phillips.   

Abstract

Our purpose was to test the hypothesis that second harmonic imaging preferentially detects backscatter from microbubbles compared with tissue structural components. A prototype second harmonic scanner was used to image a flow channel in a tissue-mimicking rubber phantom (liver density). Video time-intensity curves were calculated from repeated bolus injections of microbubble echocardiographic contrast material under the same fluid dynamic conditions but with three different imaging modes: (1) fundamental imaging at 2.5 MHz (transmit and receive at 2.5 MHz), (2) fun damental imaging at 5.0 MHz (transmit and receive at 5.0 MHz), and (3) second harmonic imaging (transmit at 2.5 MHz and receive at 5.0 MHz). Each video time-intensity curve was calibrated-such that quantitative backscatter intensity was measured relative to the tissue phantom (0 dB). The peak increase in backscatter from the contrast material in the channel relative to the tissue phantom and the intensity in the channel before the contrast effect (the noise floor) was measured along with the area under the calibrated time-intensity curve relative to the phantom. When referenced to the noise floor in the flow channel, all imaging modes produced approximately 25 dB of enhancement. However, when referenced to the tissue phantom, second harmonic imaging produced a 22.3 +/- 1.8 dB peak enhancement, which was greater than either fundamental imaging at 2.5 MHz (15.5 +/- 0.8 dB; p < 0.001) or fundamental imaging at 5.0 MHz (15.3 +/- 1.5 dB; p < 0.001). The area under the time-intensity curves confirmed that harmonic imaging has approximately 7 dB of relative enhancement to the phantom compared with fundamental imaging at either frequency. Second harmonic imaging specifically enhances backscatter from microbubbles compared with a tissue-mimicking phantom. This specificity for microbubbles is due to a decrease in backscatter for the tissue phantom, rather than an increase in backscatter for the microbubbles. These data support the hypothesis that second harmonic imaging may be able to detect microbubbles in the tissue vascular space by preferentially decreasing the backscatter from tissue structural components.

Mesh:

Substances:

Year:  1997        PMID: 9046488     DOI: 10.1016/s0894-7317(97)80027-2

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  6 in total

1.  Improved assessment of left ventricular volumes and ejection fraction by contrast enhanced harmonic color Doppler echocardiography.

Authors:  Gian Paolo Bezante; Gian Marco Rosa; Riccardo Bruni; Xucai Chen; Giuseppe Villa; Alice Scopinaro; Manrico Balbi; Antonio Barsotti; Karl Q Schwarz
Journal:  Int J Cardiovasc Imaging       Date:  2005-12       Impact factor: 2.357

2.  Effect of Transmit Beamforming on Clutter Levels in Transthoracic Echocardiography.

Authors:  Vaibhav Kakkad; Melissa LeFevre; Kingshuk Roy Choudhury; Joseph Kisslo; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2018-04-21       Impact factor: 1.578

3.  Ultrasonic evaluation of pathological brain perfusion in acute stroke using second harmonic imaging.

Authors:  J Federlein; T Postert; S Meves; S Weber; H Przuntek; T Büttner
Journal:  J Neurol Neurosurg Psychiatry       Date:  2000-11       Impact factor: 10.154

4.  Myocardial contrast echocardiography for predicting functional recovery after acute myocardial infarction.

Authors:  Adrian C Borges; Wolf S Richter; Christian Witzel; Matthias Witzel; Andrea Grohmann; Rona K Reibis; Wolfgang Rutsch; Ingeborg Küchler; Dieter L Munz; Gert Baumann
Journal:  Int J Cardiovasc Imaging       Date:  2002-08       Impact factor: 2.357

Review 5.  Current status and prospects for microbubbles in ultrasound theranostics.

Authors:  K Heath Martin; Paul A Dayton
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2013-03-15

6.  Ultrasound evaluation of normal and abnormal fetuses: comparison of conventional, tissue harmonic, and pulse-inversion harmonic imaging techniques.

Authors:  Jeong-Ah Ryu; Bohyun Kim; Sooah Kim; Soon Ha Yang; Moon Hae Choi; Hyeong Sik Ahn
Journal:  Korean J Radiol       Date:  2003 Jul-Sep       Impact factor: 3.500

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.