Literature DB >> 9042370

Influence of heavy metal ions on antibodies and immune complexes investigated by dynamic light scattering and enzyme-linked immunosorbent assay.

R Bauer1, A Müller, M Richter, K Schneider, J Frey, W Engelhardt.   

Abstract

The effect of Cd2+, Pb2+, Hg2+ and Cu2+ on the aggregation behaviour of monoclonal rat-IgG1-anti-mouse antibodies (kappa-light chain specific) and their antibody-antigen complexes with monoclonal mouse-IgG1 is reported. Investigations were done using the dynamic light scattering method. Cd2+ ions affected the hydrodynamic properties of the antibodies and the immune complex formation very little. More than 4 Cu2+ ions per antibody molecule led to large insoluble aggregates. Pb2+ ions also interacted with antibodies and immune complexes. Instead of "monomeric' antibodies (Ab) or immune complexes (Ab1Ag1), large soluble aggregates were detectable in the solution. Hg2+ ions induced complex formation with 3-4 antibodies per aggregate. Possible kinds of interaction are discussed. Additionally, we tested the antigen binding activity of metal-treated antibodies in ELISA-tests. The Sandwich ELISA technique was used to investigate the serological activity of the metal-treated antibodies, i.e., the reaction with the specific antigen. For these experiments we used the same monoclonal antibodies, mouse-IgG1 and rat-IgG1-anti-mouse. The influence of the above mentioned heavy metal ions was investigated up to a 10-fold molar excess over the antibody concentration. Even at these "unphysiological' high metal ion concentrations an inhibition of the antibody-antigen binding activity was not detectable.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9042370     DOI: 10.1016/s0304-4165(96)00078-5

Source DB:  PubMed          Journal:  Biochim Biophys Acta        ISSN: 0006-3002


  3 in total

1.  Multi-color single particle tracking with quantum dots.

Authors:  Eva C Arnspang; Jonathan R Brewer; B Christoffer Lagerholm
Journal:  PLoS One       Date:  2012-11-14       Impact factor: 3.240

2.  Matrix Effects on the Microcystin-LR Fluorescent Immunoassay Based on Optical Biosensor.

Authors:  Feng Long; An-Na Zhu; Jian-Wu Sheng; Miao He; Han-Chang Shi
Journal:  Sensors (Basel)       Date:  2009-04-23       Impact factor: 3.576

3.  Simultaneous multi-species tracking in live cells with quantum dot conjugates.

Authors:  Mathias P Clausen; Eva C Arnspang; Byron Ballou; James E Bear; B Christoffer Lagerholm
Journal:  PLoS One       Date:  2014-06-03       Impact factor: 3.240