Literature DB >> 9042172

Ineffectiveness of latex condoms in preventing contamination of the transvaginal ultrasound transducer head.

J M Storment1, M Monga, J D Blanco.   

Abstract

The efficacy of condoms in preventing contamination of the transvaginal ultrasound transducer head and possible transmission of blood-borne pathogens is unknown. Our objective was to determine the rate of contamination of the transvaginal ultrasound probe after use in the emergency department. After indicated transvaginal ultrasound scans, the latex condom was removed and the transducer head was inspected for contamination. The presence of vaginal bleeding and the duration of the ultrasound scan were noted. Ten milliliters of hydrogen peroxide (H2O2) was placed in the condom. Bubbling, which occurs in the presence of blood or cervicovaginal secretions, was considered a positive test. Exposure of a clean condom or coupling gel to H2O2 did not cause bubbling. Two-tailed Fisher's Exact and Student's t tests were used for statistical analysis. Of 173 cases, 8 (5%) had a positive H2O2 test for contamination. In only 3 of these 8 cases was gross contamination seen. Latex condoms are ineffective in preventing contamination of the transvaginal ultrasound transducer head. Visual inspection of the transducer head often fails to identify the presence of blood or body fluids. This suggests that additional measures should be taken to prevent transmission of blood-borne pathogens.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9042172     DOI: 10.1097/00007611-199702000-00007

Source DB:  PubMed          Journal:  South Med J        ISSN: 0038-4348            Impact factor:   0.954


  6 in total

1.  Nosocomial outbreak of Klebsiella pneumoniae producing SHV-5 extended-spectrum beta-lactamase, originating from a contaminated ultrasonography coupling gel.

Authors:  O Gaillot; C Maruéjouls; E Abachin; F Lecuru; G Arlet; M Simonet; P Berche
Journal:  J Clin Microbiol       Date:  1998-05       Impact factor: 5.948

2.  Infection prevention and ultrasound probe decontamination practices in Europe: a survey of the European Society of Radiology.

Authors:  Christiane Marita Nyhsen; Hilary Humphreys; Carlos Nicolau; Gerhard Mostbeck; Michel Claudon
Journal:  Insights Imaging       Date:  2016-10-24

3.  UVC radiation as an effective disinfectant method to inactivate human papillomaviruses.

Authors:  Craig Meyers; Janice Milici; Richard Robison
Journal:  PLoS One       Date:  2017-10-31       Impact factor: 3.240

4.  Infection prevention and control in ultrasound - best practice recommendations from the European Society of Radiology Ultrasound Working Group.

Authors:  Christiane M Nyhsen; Hilary Humphreys; Roland J Koerner; Nicolas Grenier; Adrian Brady; Paul Sidhu; Carlos Nicolau; Gerhard Mostbeck; Mirko D'Onofrio; Afshin Gangi; Michel Claudon
Journal:  Insights Imaging       Date:  2017-11-27

5.  Hepatitis C transmission after prostate biopsy.

Authors:  Karim Ferhi; Morgan Rouprêt; Pierre Mozer; Guillaume Ploussard; Alain Haertig; Alexandre de La Taille
Journal:  Case Rep Urol       Date:  2013-02-21

6.  High risk HPV contamination of endocavity vaginal ultrasound probes: an underestimated route of nosocomial infection?

Authors:  Jean-sebastien Casalegno; Karine Le Bail Carval; Daniel Eibach; Marie-Laure Valdeyron; Gery Lamblin; Hervé Jacquemoud; Georges Mellier; Bruno Lina; Pascal Gaucherand; Patrice Mathevet; Yahia Mekki
Journal:  PLoS One       Date:  2012-10-24       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.