Literature DB >> 9039617

MR angiography with an ultrasmall superparamagnetic iron oxide blood pool agent.

Y Anzai1, M R Prince, T L Chenevert, J H Maki, F Londy, M London, S J McLachlan.   

Abstract

The purpose of the study was to investigate the use of a dextran-coated ultrasmall superparamagnetic iron oxide (USPIO) as a blood pool contrast agent for thoracic and abdominal MR angiography. Abdominal and thoracic MR angiography was performed in six healthy volunteers using two-dimensional and three-dimensional spoiled gradient echo (SPGR) sequences before and after intravenous administration of USPIO. Doses ranged from 1.1 to 2.6 mg Fe/kg. Flip angle was varied from 20 to 60 degrees. Subjective image quality, analysis of signal-to-noise ratio (SNR), and blood T1 relaxation times were measured. USPIO significantly lowered the T1 of blood (from 1,210 ms precontrast to 159 ms postcontrast at a dose of 2.6 mg Fe/kg) (P < .01). Image quality on coronal fast three-dimensional breath-hold SPGR images of the abdomen increased with increasing dose and was maximum at the highest dose, producing an aortic SNR of 9.6 compared to 1.8 precontrast. Axial two-dimensional time-of-flight (TOF) aortic SNR was reduced significantly from 13 on precontrast to 6 on the postcontrast images at the highest dose (P < .05) due to T2* shortening effects. There was little flip angle dependence on image quality. Due to the T1 shortening effect and long intravascular half-life, USPIO improved visualization of vascular anatomy using three-dimensional fast SPGR imaging. The echo time must be minimized to minimize signal loss from T2* shortening effects. The blood pool distribution of USPIO is useful for equilibrium-phase MR angiography.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9039617     DOI: 10.1002/jmri.1880070132

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  25 in total

1.  Multicenter phase-II trial of safety and efficacy of NC100150 for steady-state contrast-enhanced peripheral magnetic resonance angiography.

Authors:  Tim Leiner; Kai Yiu J A M Ho; Vincent B Ho; Georg Bongartz; Willem P T M Mali; Wenche Rasch; Jos M A van Engelshoven
Journal:  Eur Radiol       Date:  2003-01-18       Impact factor: 5.315

Review 2.  Magnetic resonance molecular imaging with nanoparticles.

Authors:  Gregory M Lanza; Patrick M Winter; Shelton D Caruthers; Anne M Morawski; Anne H Schmieder; Katherine C Crowder; Samuel A Wickline
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

Review 3.  [Molecular and parametric imaging with iron oxides].

Authors:  L Matuszewski; B Tombach; W Heindel; C Bremer
Journal:  Radiologe       Date:  2007-01       Impact factor: 0.635

Review 4.  Contrast-enhanced magnetic resonance venography in pediatric patients with chronic kidney disease: initial experience with ferumoxytol.

Authors:  Aarti Luhar; Sarah Khan; J Paul Finn; Shahnaz Ghahremani; Rachel Griggs; Joshua Zaritsky; Isidro Salusky; Theodore R Hall
Journal:  Pediatr Radiol       Date:  2016-04-08

Review 5.  Nanomedicine strategies for molecular targets with MRI and optical imaging.

Authors:  Dipanjan Pan; Shelton D Caruthers; Junjie Chen; Patrick M Winter; Angana SenPan; Anne H Schmieder; Samuel A Wickline; Gregory M Lanza
Journal:  Future Med Chem       Date:  2010-03       Impact factor: 3.808

Review 6.  Cardiac Magnetic Resonance Quantification of Structure-Function Relationships in Heart Failure.

Authors:  Kim-Lien Nguyen; Peng Hu; J Paul Finn
Journal:  Heart Fail Clin       Date:  2020-10-28       Impact factor: 3.179

7.  High-resolution magnetic resonance angiography in the mouse using a nanoparticle blood-pool contrast agent.

Authors:  Gabriel P Howles; Ketan B Ghaghada; Yi Qi; Srinivasan Mukundan; G Allan Johnson
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

8.  Conquering the dark side: colloidal iron oxide nanoparticles.

Authors:  Angana Senpan; Shelton D Caruthers; Ilsu Rhee; Nicholas A Mauro; Dipanjan Pan; Grace Hu; Michael J Scott; Ralph W Fuhrhop; Patrick J Gaffney; Samuel A Wickline; Gregory M Lanza
Journal:  ACS Nano       Date:  2009-12-22       Impact factor: 15.881

Review 9.  Cerebral blood volume MRI with intravascular superparamagnetic iron oxide nanoparticles.

Authors:  Seong-Gi Kim; Noam Harel; Tao Jin; Tae Kim; Phil Lee; Fuqiang Zhao
Journal:  NMR Biomed       Date:  2012-12-04       Impact factor: 4.044

10.  Positive contrast with alternating repetition time SSFP (PARTS): a fast imaging technique for SPIO-labeled cells.

Authors:  Tolga Cukur; Mayumi Yamada; William R Overall; Phillip Yang; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.