Literature DB >> 9038547

Quick and simple distal pancreatectomy using the GIA stapler: report of 35 cases.

Y Kajiyama1, M Tsurumaru, H Udagawa, K Tsutsumi, Y Kinoshita, H Akiyama.   

Abstract

Mesh:

Year:  1996        PMID: 9038547     DOI: 10.1002/bjs.1800831216

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


× No keyword cloud information.
  24 in total

1.  Application of polyethylene glycolic acid felt with fibrin sealant to prevent postoperative pancreatic fistula in pancreatic surgery.

Authors:  Toshiya Ochiai; Teruhisa Sonoyama; Koji Soga; Koji Inoue; Hisashi Ikoma; Atsushi Shiozaki; Yoshiaki Kuriu; Takeshi Kubota; Masayoshi Nakanishi; Shojiro Kikuchi; Daisuke Ichikawa; Hitoshi Fujiwara; Chouhei Sakakura; Kazuma Okamoto; Yukihito Kokuba; Eigo Otsuji
Journal:  J Gastrointest Surg       Date:  2010-02-23       Impact factor: 3.452

2.  Decreasing pancreatic leak after distal pancreatectomy: saline-coupled radiofrequency ablation in a porcine model.

Authors:  Mark J Truty; Mark D Sawyer; Florencia G Que
Journal:  J Gastrointest Surg       Date:  2007-08       Impact factor: 3.452

Review 3.  Perioperative management of distal pancreatectomy.

Authors:  Yasuhiro Fujino
Journal:  World J Gastroenterol       Date:  2015-03-21       Impact factor: 5.742

4.  Prolonged peri-firing compression with a linear stapler prevents pancreatic fistula in laparoscopic distal pancreatectomy.

Authors:  Masafumi Nakamura; Junji Ueda; Hiroshi Kohno; Mohamed Yahia F Aly; Shunichi Takahata; Shuji Shimizu; Masao Tanaka
Journal:  Surg Endosc       Date:  2010-08-21       Impact factor: 4.584

5.  Complication analysis of distal pancreatectomy based on early personal experience.

Authors:  Sung-Jin Park; Hyung-Il Seo; Soo-Hee Go; Sung-Pil Yun; Ji-Yeon Lee
Journal:  Korean J Hepatobiliary Pancreat Surg       Date:  2011-12-15

6.  Novel surgical technique to prevent pancreatic fistula in distal pancreatectomy using a patch of the falciform ligament.

Authors:  Yasuhiro Fujino; Hiroyoshi Sendo; Taro Oshikiri; Takemi Sugimoto; Masahiro Tominaga
Journal:  Surg Today       Date:  2014-06-10       Impact factor: 2.549

7.  Risk factors associated with pancreatic fistula after distal pancreatectomy, which technique of pancreatic stump closure is more beneficial?

Authors:  Marco Pericoli Ridolfini; Sergio Alfieri; Stavros Gourgiotis; Dario Di Miceli; Fabio Rotondi; Giuseppe Quero; Roberta Manghi; Giovanni Battista Doglietto
Journal:  World J Gastroenterol       Date:  2007-10-14       Impact factor: 5.742

8.  Analysis of closure of the pancreatic remnant after distal pancreatic resection.

Authors:  U Lorenz; M Maier; U Steger; C Töpfer; A Thiede; S Timm
Journal:  HPB (Oxford)       Date:  2007       Impact factor: 3.647

9.  Absorbable mesh reinforcement of a stapled pancreatic transection line reduces the leak rate with distal pancreatectomy.

Authors:  Reuben I Thaker; Brent D Matthews; David C Linehan; Steven M Strasberg; J Chris Eagon; William G Hawkins
Journal:  J Gastrointest Surg       Date:  2007-01       Impact factor: 3.452

10.  Complications of pancreatic surgery.

Authors:  Choon-Kiat Ho; Jörg Kleeff; Helmut Friess; Markus W Büchler
Journal:  HPB (Oxford)       Date:  2005       Impact factor: 3.647

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.