| Literature DB >> 9035406 |
M Okochi1, T K Lim, N Nakamura, T Matsunaga.
Abstract
An electrochemical reactor employing activated carbon fibers (ACF) was constructed for the disinfection of bacteria in drinking water. The application of an alternating potential of 1.0 V and -0.8 V versus a saturated calomel electrode, for disinfecting and desorbing bacteria, enabled reactor operation for 840 h. Drinking water was passed through the reactor in stop/flow mode: 300 ml/min flow for 12 h and no flow for 12 h, alternately. The bacterial cell density in treated water was always been less than 20 cells/ml. It was also found that the formation of biofilm on the ACF reactor caused an increase in current, enabling the self-detection of microbial fouling.Entities:
Mesh:
Substances:
Year: 1997 PMID: 9035406 DOI: 10.1007/s002530050882
Source DB: PubMed Journal: Appl Microbiol Biotechnol ISSN: 0175-7598 Impact factor: 4.813