Development of an implantable ventricular assist system.

M P Macris1, S M Parnis, O H Frazier, J M Fuqua, R K Jarvik.   

Abstract

BACKGROUND: This study describes the present state of progress in the development of the Jarvik 2000 ventricular assist system.
METHODS: Designed for implantation in the human thorax, the system consists of a small (25 cm3, 90 g) intraventricular axial-flow blood pump that transmits power and data via internal electronics and a transcutaneous energy transfer system. The pump is powered by portable internal and external polymer lithium ion batteries. The only moving part, the pump rotor, contains a permanent magnet of a brushless direct-current motor that mounts an axial-flow impeller and partial magnetic thrust support, with blood-immersed radial and thrust bearings. The motor uses a redundant coil and electric lead design, which permits continued operation in case of wire breakage.
RESULTS: Seven calves have been supported for an average of 107 days (range, 40 to 162 days) with prototypes of the Jarvik 2000 ventricular assist system. No physiologic complications have occurred. When its user is at rest, the pump produces flows of 5 to 6 L/min with a decreased arterial pulse contour. Renal and hepatic functions have remained normal throughout the duration of all studies. Mean plasma free hemoglobin levels ranged from 4.3 to 11.4 mg/dL (mean, 6.3 mg/dL) for each study. Pathologic analyses of the heart and kidneys revealed no damage related to the device.
CONCLUSIONS: These studies indicate that the Jarvik 2000 ventricular assist system is feasible in animals and holds promise for long-term support of patients.

Entities:  

Mesh:

Year:  1997        PMID: 9033302     DOI: 10.1016/s0003-4975(96)01226-x

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Long-term durability test of axial-flow ventricular assist device under pulsatile flow.

Authors:  Masahiro Nishida; Ryo Kosaka; Osamu Maruyama; Takashi Yamane; Akio Shirasu; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2016-11-04       Impact factor: 1.731

2.  Flow features and device-induced blood trauma in CF-VADs under a pulsatile blood flow condition: A CFD comparative study.

Authors:  Zengsheng Chen; Sofen K Jena; Guruprasad A Giridharan; Steven C Koenig; Mark S Slaughter; Bartley P Griffith; Zhongjun J Wu
Journal:  Int J Numer Method Biomed Eng       Date:  2017-10-06       Impact factor: 2.747

3.  Finite state machine implementation for left ventricle modeling and control.

Authors:  Jacob M King; Clint A Bergeron; Charles E Taylor
Journal:  Biomed Eng Online       Date:  2019-01-30       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.