Literature DB >> 9031859

Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution.

K J Blissitt1, L E Young, R S Jones, P G Darke, J Utting.   

Abstract

Measurement of cardiac output by Doppler echocardiography were compared to simultaneous measurements by thermodilution in 9 conscious horses. In the Doppler technique, mean blood flow velocities for estimation of cardiac output were recorded from the aorta and pulmonary artery. The flow area of each vessel was calculated from the vessel diameter, measured from a 2-dimensional ultrasound image. Differences in the site and method of measuring the vessel diameter altered the estimation of cardiac output by the Doppler method. Cardiac output was modified by the i.v. infusion of 4 micrograms/kg bwt/min dopamine and 4 micrograms/kg bwt/min dobutamine and by the i.v. administration of 10 micrograms/kg bwt detomidine and 20 micrograms/kg bwt butorphanol. Doppler measurements of cardiac output correlated closely with measurement by thermodilution. Measurements from the aortic outflow correlated more closely with thermodilution, than those from the pulmonary artery (r = 0.89 and r = 0.77, respectively). Doppler measurements when the mean flow velocity was recorded from the aorta and the flow area was measured from the ascending aorta using the leading edge method. There was no significant bias between the 2 techniques when Doppler flow velocities were recorded by this method and the limits of agreement were narrow (+/- 12.26 l/min). The differences between the 2 methods increased with increasing cardiac output. Doppler echocardiography is a safe noninvasive method of measuring cardiac output in horses. The agreement between Doppler echocardiography and thermodilution in this study is similar to that reported in man and is similar to that reported between thermodilution and other techniques in man.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9031859     DOI: 10.1111/j.2042-3306.1997.tb01631.x

Source DB:  PubMed          Journal:  Equine Vet J        ISSN: 0425-1644            Impact factor:   2.888


  2 in total

1.  Comparison of systolic cardiac function before and after treatment of atrial fibrillation in horses with and without additional cardiac valve insufficiencies.

Authors:  H Gehlen; P Stadler
Journal:  Vet Res Commun       Date:  2004-05       Impact factor: 2.459

2.  Three-dimensional and catheter-based intracardiac echocardiographic characterization of the interatrial septum in 2 horses with suspicion of a patent foramen ovale.

Authors:  Ingrid Vernemmen; Ellen Paulussen; Julie Dauvillier; Annelies Decloedt; Gunther van Loon
Journal:  J Vet Intern Med       Date:  2022-05-30       Impact factor: 3.175

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.