Literature DB >> 9030350

A flexible metal ventricular catheter for treatment of complicated and protracted infections of the cerebrospinal fluid spaces: preliminary experiences.

U Vieweg1, B Kaden, D Van Roost.   

Abstract

In the management of shunt infection, the use of ventricular catheters made of silicone rubber for the temporary external drainage of cerebrospinal fluid (CSF) is general practice. However, the eradication of the primary source of infection may be hindered by the affinity of bacteria to silicone-based material. Compared to silicone catheters, a metal drainage device for temporary ventriculostomy appears to offer more favourable conditions for successful eradication of the infection. Since metal needles cannot be implanted permanently and since their screw-type fixation precludes attachment to the skulls of infants or small children, we developed a flexible metal catheter. This catheter was used exclusively for the treatment of particularly serious or chronic infections of the CSF spaces. The catheter is made of implantation steel and consists of a corrugated tube that renders it flexible. Cerebrospinal fluid drains into a receptable bulb at the tip of the tube. Tubing of other materials may be connected to the end of the metal catheter for either external or internal drainage. It was implanted as a temporary and later permanent CSF drainage in 7 male patients aged from 4 to 60 years, who suffered from chronic, recurrent ventriculitis (n = 5) with an average of 7 previous surgical revisions, as well as from complex infections (n = 2; basal tuberculous meningitis, brain abscess). The infections were successfully eliminated in 6 patients. In the remaining patient, the metal catheter for external ventriculostomy had to be removed after 4 days due a leakage of CSF; it was replaced by a silicone catheter and later on by a needle drainage. Other complications, such as secondary infection or intracerebral haemorrhage, did not occur. The average duration of external CSF drainage via the flexible metal catheter was 27 days (range 4-50 days). In 4 patients, the CSF drainage was converted to a permanent ventriculoperitoneal shunt using a new flexible metal catheter. At the time of post-operative follow-up examination (average = 34 weeks), all shunts were functioning and there was no evidence of infection. In cases of especially complicated and protracted CSF infections, the flexible metal ventricular catheter is a promising device for treatment.

Entities:  

Mesh:

Year:  1996        PMID: 9030350     DOI: 10.1007/bf01411122

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  23 in total

1.  Infections complicating the use of external ventriculostomy.

Authors:  R W Smith; J F Alksne
Journal:  J Neurosurg       Date:  1976-05       Impact factor: 5.115

2.  [Diagnostic and therapeutic value of percutaneous twist-drill puncture and needle exploration (author's transl)].

Authors:  J Gilsbach; M Schumacher
Journal:  Neurochirurgia (Stuttg)       Date:  1978-07

3.  Ventricle puncture for external CSF drainage and pressure measurement using a modified puncture needle.

Authors:  W Hassler; J Zentner
Journal:  Acta Neurochir (Wien)       Date:  1988       Impact factor: 2.216

4.  Prolonged therapeutic external ventricular drainage: a prospective study.

Authors:  K H Chan; K S Mann
Journal:  Neurosurgery       Date:  1988-10       Impact factor: 4.654

5.  Production of extra-cellular slime by Staphylococcus epidermidis during stationary phase of growth: its association with adherence to implantable devices.

Authors:  R Bayston; J Rodgers
Journal:  J Clin Pathol       Date:  1990-10       Impact factor: 3.411

6.  Prolonged external ventricular drainage with percutaneous long-tunnel ventriculostomies.

Authors:  R K Khanna; M L Rosenblum; J P Rock; G M Malik
Journal:  J Neurosurg       Date:  1995-11       Impact factor: 5.115

7.  [Actinomycosis infection of the cerebellum].

Authors:  A Schwarz; J J Langmayr; M Ortler; M Fille
Journal:  Wien Klin Wochenschr       Date:  1993       Impact factor: 1.704

8.  Citrobacter diversus ventriculitis and brain abscesses in an adult.

Authors:  L V Booth; J D Palmer; J Pateman; A C Tuck
Journal:  J Infect       Date:  1993-03       Impact factor: 6.072

Review 9.  New considerations in the pathogenesis of coagulase-negative staphylococcal foreign body infections.

Authors:  G Peters
Journal:  J Antimicrob Chemother       Date:  1988-04       Impact factor: 5.790

View more
  1 in total

Review 1.  Hemorrhagic complications of ventriculostomy placement: a meta-analysis.

Authors:  Daniel D Binz; L Gerard Toussaint; Jonathan A Friedman
Journal:  Neurocrit Care       Date:  2009-02-18       Impact factor: 3.210

  1 in total