Literature DB >> 9029451

The effectiveness of an aerosol reduction device for ultrasonic scalers.

T B King1, K B Muzzin, C W Berry, L M Anders.   

Abstract

Intraoral use of ultrasonic scalers may generate aerosols that contain infectious microorganisms and therefore pose a hazard to the health of the dental professional. The purpose of this in vivo study was to determine if an aerosol reduction device for an ultrasonic scaler would be effective in reducing the amount of contaminated aerosols produced during ultrasonic instrumentation. Twelve adult subjects participated in the study. A split-mouth design was utilized, and two treatments (in separate rooms) were performed on each subject: 1) ultrasonic scaling for 5 minutes with the aerosol reduction device; and 2) ultrasonic scaling for 5 minutes without the aerosol reduction device. The right or left side of the subject's mouth was randomly assigned to one of the two treatment groups. After instrumentation, the subject and operator remained motionless for 25 minutes during collection of aerosol particles. Air samples were collected on blood agar plates 6 inches from the subject's mouth. Replicate organism detection and counting plates were used to sample microorganisms present on the investigator's face shield. All plates were incubated for 3 days at 37 degrees C. The results, using the paired t-test (P < 0.001), indicate that the ultrasonic scaler without the aerosol reduction device had a significantly greater quantity of mean colony forming units (CFUs) 6 inches from the subject's mouth (45.1 +/- 28.9) than the ultrasonic scaler with the aerosol reduction device (2.6 +/- 3.6). No significant difference was evident in the number of CFUs found on the investigator's face shield. These data suggest that an aerosol reduction device is effective in reducing the number of microorganisms generated during ultrasonic scaling, therefore decreasing the risk of disease transmission.

Mesh:

Substances:

Year:  1997        PMID: 9029451     DOI: 10.1902/jop.1997.68.1.45

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  19 in total

1.  Evaluation of environmental bacterial contamination and procedures to control cross infection in a sample of Italian dental surgeries.

Authors:  S Monarca; M Grottolo; D Renzi; C Paganelli; P Sapelli; I Zerbini; G Nardi
Journal:  Occup Environ Med       Date:  2000-11       Impact factor: 4.402

2.  Risk factors associated with asthma phenotypes in dental healthcare workers.

Authors:  Tanusha Singh; Braimoh Bello; Mohamed F Jeebhay
Journal:  Am J Ind Med       Date:  2012-04-02       Impact factor: 2.214

3.  Evaluation of Aerosol and Water Contamination and Control of Cross Infection in Dental Clinics.

Authors:  T Prasanth; V B Mandlik; S Kumar; A K Jha; M Kosala
Journal:  Med J Armed Forces India       Date:  2011-07-21

4.  Sources of SARS-CoV-2 and Other Microorganisms in Dental Aerosols.

Authors:  A P Meethil; S Saraswat; P P Chaudhary; S M Dabdoub; P S Kumar
Journal:  J Dent Res       Date:  2021-05-12       Impact factor: 8.924

5.  Interventions to reduce contaminated aerosols produced during dental procedures for preventing infectious diseases.

Authors:  Sumanth Kumbargere Nagraj; Prashanti Eachempati; Martha Paisi; Mona Nasser; Gowri Sivaramakrishnan; Jos H Verbeek
Journal:  Cochrane Database Syst Rev       Date:  2020-10-12

6.  Efficacy of High-volume Evacuator in Aerosol Reduction: Truth or Myth? A Clinical and Microbiological Study.

Authors:  Hitesh Desarda; Abhijit Gurav; Chandrakant Dharmadhikari; Abhijeet Shete; Subodh Gaikwad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-09-17

7.  Qualitative and quantitative analysis of bacterial aerosols in dental clinical settings: Risk exposure towards dentist, auxiliary staff, and patients.

Authors:  Manish Jain; Aditi Mathur; Anmol Mathur; Pravin U Mukhi; Mahesh Ahire; Chadrashekhar Pingal
Journal:  J Family Med Prim Care       Date:  2020-02-28

8.  Italian multicenter study on infection hazards during dental practice: control of environmental microbial contamination in public dental surgeries.

Authors:  Paolo Castiglia; Giorgio Liguori; Maria Teresa Montagna; Christian Napoli; Cesira Pasquarella; Margherita Bergomi; Leila Fabiani; Silvano Monarca; Stefano Petti
Journal:  BMC Public Health       Date:  2008-05-29       Impact factor: 3.295

9.  A clinical investigation of dental evacuation systems in reducing aerosols.

Authors:  Montry S Suprono; John Won; Roberto Savignano; Zhe Zhong; Abu Ahmed; Gina Roque-Torres; Wu Zhang; Udochukwu Oyoyo; Paul Richardson; Joseph Caruso; Robert Handysides; Yiming Li
Journal:  J Am Dent Assoc       Date:  2021-06       Impact factor: 3.634

10.  The efficacy of an extraoral scavenging device on reduction of splatter contamination during dental aerosol generating procedures: an exploratory study.

Authors:  Shakeel Shahdad; Tulsi Patel; Annika Hindocha; Neil Cagney; Jens-Dominik Mueller; Noha Seoudi; Claire Morgan; Ahmed Din
Journal:  Br Dent J       Date:  2020-09-11       Impact factor: 2.727

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.