Literature DB >> 9028999

Hemostatic efficacy and safety of TachoComb in surgery. Ready to use and rapid hemostatic agent.

G B Agus1, A V Bono, E Mira, S Olivero, A Peilowich, E Homdrum, C Benelli.   

Abstract

TachoComb is a new, ready-to-use hemostatic agent consisting of a collagen sheet coated on one side with human fibrinogen, bovine thrombin, and bovine aprotinin. The product was used in 125 surgical operations (vascular, hepatic, urological and ENT) in which secondary hemostasis was required. It was placed over the cut surface or over the edges of the wound. The investigating surgeons expressed their opinion on the intra- and postoperative hemostatic efficacy, and routine laboratory tests were done postoperatively. TachoComb had good hemostatic efficacy in 67.2% of cases, and very good in 22.4%. No noteworthy systemic changes were observed. As an adjuvant to obtain complete hemostasis in surgery, TachoComb is effective, practical and quick to use, and is very well tolerated.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9028999

Source DB:  PubMed          Journal:  Int Surg        ISSN: 0020-8868


  4 in total

1.  The use of novel hemostatic sealant (Tisseel) in laparoscopic myomectomy: a case-control study.

Authors:  Roberto Angioli; Francesco Plotti; Roberto Ricciardi; Corrado Terranova; Marzio Angelo Zullo; Patrizio Damiani; Roberto Montera; Federica Guzzo; Giuseppe Scaletta; Ludovico Muzii
Journal:  Surg Endosc       Date:  2012-02-01       Impact factor: 4.584

2.  A simple application technique of fibrin-coated collagen fleece (TachoComb) in laparoscopic surgery.

Authors:  Kiyokazu Nakajima; Keigo Yasumasa; Shunji Endo; Tsuyoshi Takahashi; Yasuyuki Kai; Riichiro Nezu; Toshirou Nishida
Journal:  Surg Today       Date:  2007-01-25       Impact factor: 2.549

3.  Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial.

Authors:  Andrea Frilling; Gregor A Stavrou; Hans-Jörg Mischinger; Bernard de Hemptinne; Mogens Rokkjaer; Jürgen Klempnauer; Anders Thörne; Beat Gloor; Susanne Beckebaum; Mohamed F A Ghaffar; Christoph E Broelsch
Journal:  Langenbecks Arch Surg       Date:  2005-02-19       Impact factor: 3.445

4.  Efficacy of TachoSil patches in controlling Dacron suture-hole bleeding after abdominal aortic aneurysm open repair.

Authors:  Guido Bajardi; Felice Pecoraro; Domenico Mirabella
Journal:  J Cardiothorac Surg       Date:  2009-11-04       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.