Literature DB >> 9025127

ACD versus standard CPR in a prehospital setting.

W Panzer1, M Bretthauer, H Klingler, J Bahr, J Rathgeber, D Kettler.   

Abstract

BACKGROUND: Animal and human studies in cardiac arrest demonstrate significant improvements in systolic blood pressure, coronary perfusion pressure and total brain and myocardial blood flow with active compression-decompression (ACD) cardiopulmonary resuscitation (CPR). The results of recent studies in patients with out-of-hospital cardiac arrest and use of ACD-CPR are non-uniform and require supplementation.
METHODS: In a retrospective non-randomised design, 152 adult patients with prehospital cardiac arrest, not caused by trauma or hypothermia, were studied. Compressions were performed according to the recommendations of the American Heart Association. Three ACD devices were assigned to seven rescue units changing monthly. Study end-points were the rates of return of spontaneous circulation (ROSC), admission to hospital, survival at 24h, hospital discharge and neurologic outcome.
RESULTS: 70 (46%) patients underwent standard (STD) CPR and 82 (54%) patients were treated with ACD-CPR. Both groups were comparable with regard to age, sex, witnessed cardiac arrests, bystander CPR, cause of arrest, time intervals, number of defibrillations, and total amount of epinephrine. No significant differences in outcome could be found: 20 patients (29%) who received STD-CPR, and 14 patients (17%) who underwent ACD-CPR survived to hospital discharge. Neither at other end-points nor in any subgroups could any significant differences be discovered. Patients regaining ROSC showed a significant difference in favour of STD-CPR for the end-points of hospital admission, 24-h survival and hospital discharge.
CONCLUSION: No significant differences in hospital discharge and neurological outcome were found between STD-CPR and ACD-CPR.

Entities:  

Mesh:

Year:  1996        PMID: 9025127     DOI: 10.1016/s0300-9572(96)01021-0

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  2 in total

Review 1.  [Mechanical resuscitation assist devices].

Authors:  M Fischer; M Breil; M Ihli; M Messelken; S Rauch; J-C Schewe
Journal:  Anaesthesist       Date:  2014-03       Impact factor: 1.041

Review 2.  Active chest compression-decompression for cardiopulmonary resuscitation.

Authors:  Carmelo Lafuente-Lafuente; María Melero-Bascones
Journal:  Cochrane Database Syst Rev       Date:  2013-09-20
  2 in total