Literature DB >> 9019464

[Exposure of operating room personnel to anesthetic gases during ENT interventions].

K Hoerauf1, W Hosemann, K Wild, J Hobbhahn.   

Abstract

During ENT surgical procedures under general anesthesia contamination of the operating room air through waste anesthetic gases seems unavoidable. A resulting chronic low-level exposure to anesthetic gases in subanesthetic concentrations (m1/m3 = ppm) may cause various negative health effects. The aim of this study was to quantify possible side effects on operating room personnel. By using a highly sensitive, direct reading instrument for determining contamination leakage from a patient's mouth and resulting concentrations in the breathing zone of the surgeon and anesthetist, levels of isoflurane and nitrous oxide were measured at 2-min intervals during 20 ENT surgical procedures performed under usual workplace conditions. Despite high concentrations of anesthetic at the mouth of each patient, personnel-related mean values remained under recommended threshold values (TLV) of 10 ppm isoflurane. A TLV of 100 ppm nitrous oxide was exceeded in 20% of the operations. Furthermore, a safe TLV for pregnant staff was 25 ppm nitrous oxide. This value was exceeded during nearly all operations (93%) for the group "surgeon". High leakages at the patient's mouth led to an undesirably high contamination of operating room personnel by nitrous oxide. Although threshold values were mostly not exceeded in available working conditions (i.e., adequate air conditioning and intubation cuff pressure control), present health and safety regulations concerning pregnant women showed that the values of nitrous oxide were still too high to allow such women to work safely in operating rooms during surgery. However, exposure to isoflurane was too slight to classify.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9019464     DOI: 10.1007/s001060050055

Source DB:  PubMed          Journal:  HNO        ISSN: 0017-6192            Impact factor:   1.284


  3 in total

Review 1.  Occupational exposure to volatile anaesthetics: epidemiology and approaches to reducing the problem.

Authors:  C Byhahn; H J Wilke; K Westpphal
Journal:  CNS Drugs       Date:  2001       Impact factor: 5.749

2.  Environmental and biological measurements of isoflurane and sevoflurane in operating room personnel.

Authors:  Abbas Jafari; Rogaieh Bargeshadi; Fatemeh Jafari; Iraj Mohebbi; Mohammad Hajaghazadeh
Journal:  Int Arch Occup Environ Health       Date:  2017-12-15       Impact factor: 3.015

3.  [Propofol for paediatric patients in ear, nose and throat surgery. Practicability, quality and cost-effectiveness of different anaesthesia procedures for adenoidectomy in infants].

Authors:  K Auerswald; K Behrends; U Burkhardt; D Olthoff
Journal:  Anaesthesist       Date:  2006-08       Impact factor: 1.041

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.