Literature DB >> 9008730

Simple and reliable enumeration of micronucleated reticulocytes with a single-laser flow cytometer.

S D Dertinger1, D K Torous, K R Tometsko.   

Abstract

A flow cytometric procedure for scoring micronuclei in mouse peripheral blood erythrocytes, especially reticulocytes, is described. The methods reported herein were developed in an effort to simplify the techniques and to reduce the equipment requirements associated with automated micronucleus analyses. With this procedure, fluorescein-conjugated monoclonal antibodies which bind to the CD71-defined antigen (the transferrin receptor) are used to label reticulocytes. The nucleic acid dye propidium iodide is used to identify cells with micronuclei. Given 488 nm excitation, four populations of erythrocytes are clearly resolved: normochromatic erythrocytes with and without micronuclei, and reticulocytes with and without micronuclei. Since the method is capable of simultaneously providing the incidence of micronuclei in both mature and immature erythrocyte populations, it is compatible with either chronic or acute treatment regimens. To demonstrate cell handling and flow cytometric procedures for quantitatively analyzing peripheral blood micronuclei, an experiment with the model clastogen methyl methanesulfonate is described. Additionally, a reconstruction experiment was performed whereby three mouse blood samples were spiked with successively greater volumes of blood from a clastogen-treated animal so each preparation differed slightly, but definitely, in micronucleus content. Each sample was scored six times by conventional microscopy and by flow cytometry so that the two methods could be directly compared. Collectively, the results from the methyl methanesulfonate experiment and the reconstruction study demonstrate the accuracy and reliability of the flow cytometric method. Furthermore, advantages associated with objective, high throughout scoring methodology are clearly indicated.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9008730     DOI: 10.1016/s0165-1218(96)90117-2

Source DB:  PubMed          Journal:  Mutat Res        ISSN: 0027-5107            Impact factor:   2.433


  22 in total

1.  Biological impact of low dose-rate simulated solar particle event radiation in vivo.

Authors:  P Y Chang; R Doppalapudi; J Bakke; A Wang; S Menda; Z Davis
Journal:  Radiat Environ Biophys       Date:  2010-05-16       Impact factor: 1.925

Review 2.  How accurate is in vitro prediction of carcinogenicity?

Authors:  Richard Maurice Walmsley; Nicholas Billinton
Journal:  Br J Pharmacol       Date:  2011-03       Impact factor: 8.739

3.  Analysis of Biomarkers of DNA Damage and Mutagenicity in Mice Exposed to Acrylonitrile.

Authors:  Vernon E Walker; Dale M Walker; Burhan I Ghanayem; George R Douglas
Journal:  Chem Res Toxicol       Date:  2020-06-28       Impact factor: 3.739

4.  Genome maintenance defects in cultured cells and mice following partial inactivation of the essential cell cycle checkpoint gene Hus1.

Authors:  Peter S Levitt; Min Zhu; Amy Cassano; Stephanie A Yazinski; Houchun Liu; Joshua Darfler; Rachel M Peters; Robert S Weiss
Journal:  Mol Cell Biol       Date:  2007-01-12       Impact factor: 4.272

5.  In vitro erythropoiesis from bone marrow-derived progenitors provides a physiological assay for toxic and mutagenic compounds.

Authors:  J Shuga; J Zhang; L D Samson; H F Lodish; L G Griffith
Journal:  Proc Natl Acad Sci U S A       Date:  2007-05-14       Impact factor: 11.205

6.  Sensitivity of the erythrocyte micronucleus assay: dependence on number of cells scored and inter-animal variability.

Authors:  Grace E Kissling; Stephen D Dertinger; Makoto Hayashi; James T MacGregor
Journal:  Mutat Res       Date:  2007-08-06       Impact factor: 2.433

7.  Radio-adaptive response to environmental exposures at Chernobyl.

Authors:  Brenda E Rodgers; Kristen M Holmes
Journal:  Dose Response       Date:  2008-03-13       Impact factor: 2.658

8.  A novel non-invasive method to measure splenic filtration function in humans.

Authors:  Sara El Hoss; Michaël Dussiot; Olivier Renaud; Valentine Brousse; Wassim El Nemer
Journal:  Haematologica       Date:  2018-06-07       Impact factor: 9.941

Review 9.  DNA polymerase POLQ and cellular defense against DNA damage.

Authors:  Matthew J Yousefzadeh; Richard D Wood
Journal:  DNA Repair (Amst)       Date:  2012-12-04

Review 10.  DNA polymerase θ (POLQ), double-strand break repair, and cancer.

Authors:  Richard D Wood; Sylvie Doublié
Journal:  DNA Repair (Amst)       Date:  2016-05-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.