Literature DB >> 9003928

Measurement of tendon excursion velocity with colour Doppler imaging: a preliminary study on flexor pollicis longus muscle.

B S Cigali1, H M Buyruk, C J Snijders, J S Laméris, W P Holland, R Mesut, H J Stam.   

Abstract

PURPOSE: To study the use of colour Doppler imaging (CDI) for the measurement of maximum and mean tendon velocity. Recent studies showed that CDI, normally used for blood flow examinations, can be used for the imaging of tendons at the hand and wrist region. Although other modalities are available for imaging of the muscle-skeletal system, in vivo measurements of the velocity of tendon excursion are not possible.
METHODS: The flexor pollicis longus (FPL) tendon of 16 healthy volunteers was measured bilaterally at two levels (wrist and thenar). A splint from the fingers along the proximal lower arm was applied. The thumb was fixed to the splint from the the first phalanx to allow flexion of the interphalangeal (IP) joint only. Pulsed CDI was used for the measurements. The maximum and mean velocities of the FPL tendon were measured at spectrum display mode during continuous voluntary contractions. At least 10 sequential Doppler peaks (cm/s) were recorded at every trial. The measurements were repeated three times. Paired t-test and correlation coefficients were calculated between levels on the same side and the opposite side.
RESULTS: No significant differences were found between two levels of the same hand and of the opposite hand. As expected, the data revealed variations in the inter-individual tendon velocities.
CONCLUSIONS: The velocity of the excursion of the FPL tendon can be measured with CDI with good reproducibility. It is expected that velocity measurements can be used in the future for the assessment of other tendons affected by various disorders.

Entities:  

Mesh:

Year:  1996        PMID: 9003928     DOI: 10.1016/s0720-048x(96)00767-x

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  5 in total

1.  Measurement of tendon velocities using vector tissue Doppler imaging: a feasibility study.

Authors:  Avinash Eranki; Lindsey Bellini; Laura Prosser; Christopher Stanley; Daniel Bland; Katharine Alter; Diane Damiano; Siddhartha Sikdar
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

2.  Speckle-tracking sonographic assessment of longitudinal motion of the flexor tendon and subsynovial tissue in carpal tunnel syndrome.

Authors:  Margriet H M van Doesburg; Yuichi Yoshii; Jacqueline Henderson; Hector R Villarraga; Steven L Moran; Peter C Amadio
Journal:  J Ultrasound Med       Date:  2012-07       Impact factor: 2.153

3.  Does loading velocity affect failure strength after tendon repair?

Authors:  Manoj Parimi; Chunfeng Zhao; Andrew R Thoreson; Kai-Nan An; Peter C Amadio
Journal:  J Biomech       Date:  2012-09-15       Impact factor: 2.712

4.  Speckle tracking ultrasound for assessment of the relative motion of flexor tendon and subsynovial connective tissue in the human carpal tunnel.

Authors:  Yuichi Yoshii; Hector R Villarraga; Jacqueline Henderson; Chunfeng Zhao; Kai-Nan An; Peter C Amadio
Journal:  Ultrasound Med Biol       Date:  2009-10-13       Impact factor: 2.998

5.  Transverse plane tendon and median nerve motion in the carpal tunnel: ultrasound comparison of carpal tunnel syndrome patients and healthy volunteers.

Authors:  Margriet H M van Doesburg; Jacqueline Henderson; Aebele B Mink van der Molen; Kai-Nan An; Peter C Amadio
Journal:  PLoS One       Date:  2012-05-11       Impact factor: 3.240

  5 in total