Literature DB >> 9003901

Rat sciatic nerve regeneration through a micromachined silicon chip.

Q Zhao1, J Drott, T Laurell, L Wallman, K Lindström, L M Bjursten, G Lundborg, L Montelius, N Danielsen.   

Abstract

The capacity of regenerating nerve fibres to grow through a perforated silicon chip was tested using the silicone chamber model for nerve regeneration. The chips were fabricated as circular membranes, 4 mm in diameter, thickness 60 microns, with a perforated area, 2 mm in diameter, in the centre. Three types of chips were fabricated utilizing anisotropic etching. The chips were glued with silicone adhesive between two halves of silicone rubber tubing (total length 8 mm, inner diameter 1.8 mm, outer diameter 3.0 mm) which was used to bridge a 4 mm gap between the proximal and distal nerve stumps of a transected rat sciatic nerve. The capacity of regenerating nerve fibres to grow through the holes of the chip was analysed by light and scanning electron microscopy after 4 or 16 weeks of regeneration. Furthermore, the muscle contractility force of the gastrocnemius muscle was measured after 16 weeks of regeneration and compared as a percentage of the contralateral uninjured side. Nerves generated through chips with hole diameters of 10 or 50 microns were morphological and functional failures. The nerve structures distal to chips with hole diameters of 100 microns contained many myelinated nerve fibres in a minifascicular pattern after both 4 and 16 weeks of regeneration. The muscle contractility force was 56% of that of contralateral control muscles.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9003901     DOI: 10.1016/s0142-9612(96)00112-3

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  3 in total

1.  Functional recordings from awake, behaving rodents through a microchannel based regenerative neural interface.

Authors:  Russell K Gore; Yoonsu Choi; Ravi Bellamkonda; Arthur English
Journal:  J Neural Eng       Date:  2015-01-21       Impact factor: 5.379

Review 2.  Types of neural guides and using nanotechnology for peripheral nerve reconstruction.

Authors:  Esmaeil Biazar; M T Khorasani; Naser Montazeri; Khalil Pourshamsian; Morteza Daliri; Mostafa Rezaei; Mahmoud Jabarvand; Ahad Khoshzaban; Saeed Heidari; Mostafa Jafarpour; Ziba Roviemiab
Journal:  Int J Nanomedicine       Date:  2010-10-21

3.  Regenerated Sciatic Nerve Axons Stimulated through a Chronically Implanted Macro-Sieve Electrode.

Authors:  Matthew R MacEwan; Erik R Zellmer; Jesse J Wheeler; Harold Burton; Daniel W Moran
Journal:  Front Neurosci       Date:  2016-12-08       Impact factor: 4.677

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.