Literature DB >> 9002071

Nested PCR assays with novel primers yield greater sensitivity to Tanzanian HIV-1 samples than a commercial PCR detection kit.

O Grankvist1, L Walther, U Bredberg-Rådén, E Lyamuya, F Mhalu, A Gustafsson, G Biberfeld, G Wadell.   

Abstract

To investigate the efficacy of the SK431/SK145 primer pair and two nested primer assays in amplifying African HIV-1 samples, a total of 35 Tanzanian PBMC samples were examined. These were assayed by two HIV-1 specific nested in-house PCR assays and a commercial HIV-1 PCR kit (GeneAmp) using SK431/SK145 as the primer pair. One of the nested PCR assays has been evaluated previously (old assay), whereas the modified assay was constructed from the HIV-1 sequence alignment released in August 1993. The modified nested primer assay showed increased sensitivity in the gag and env regions compared to the old nested primer assay. However, both the old and the modified nested primer assays displayed higher sensitivity for the detection of Tanzanian HIV-1 proviruses than the GeneAmp assay. When two regions were used (gag and env) as targets for the amplification, the modified nested primer assay detected 97.1% (34/35) of the proteinase K lysed samples, compared to 68.6% (24/35) using the SK431/SK145 primer pair (P < 0.01**). The results indicate that the SK431/SK145 primer pair may be less suitable when HIV-1 samples from Africa are analysed. The results also show that continuous modification of primer sequences can improve and maintain high sensitivity for the detection of highly divergent HIV-1 strains.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9002071     DOI: 10.1016/s0166-0934(96)02094-0

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  3 in total

1.  Fluorogenic LUX primer for quantitation of HIV-1 by real-time RT-PCR.

Authors:  Natela Rekhviashvili; Gwynneth Stevens; Lesley Scott; Wendy Stevens
Journal:  Mol Biotechnol       Date:  2006-02       Impact factor: 2.695

2.  Overestimation of human immunodeficiency virus type 1 load caused by the presence of cells in plasma from plasma preparation tubes.

Authors:  Anne-Marte Bakken Kran; Tom Øystein Jonassen; Mette Sannes; Kirsti Jakobsen; Andreas Lind; Arild Maeland; Mona Holberg-Petersen
Journal:  J Clin Microbiol       Date:  2009-05-06       Impact factor: 5.948

3.  Antimicrobial resistance predicts death in Tanzanian children with bloodstream infections: a prospective cohort study.

Authors:  Bjørn Blomberg; Karim P Manji; Willy K Urassa; Bushir S Tamim; Davis S M Mwakagile; Roland Jureen; Viola Msangi; Marit G Tellevik; Mona Holberg-Petersen; Stig Harthug; Samwel Y Maselle; Nina Langeland
Journal:  BMC Infect Dis       Date:  2007-05-22       Impact factor: 3.090