Reproducibility of electrical impedance tomographic spectroscopy (EITS) parametric images of neonatal lungs.

S S Marven1, A R Hampshire, R H Smallwood, B H Brown, R A Primhak.   

Abstract

The reproducibility of electrical impedance tomographic spectroscopy (EITS) images of neonatal lungs have been investigated in 11 clinically stable babies. We have used the Sheffield Mark IIIa EITS system. An average inspiration frame was generated from the data frames associated with maximum inspiration. Frequency images were reconstructed from these frames. The frequency images were analysed to locate the pixel with the maximum change in the right lung field. The change was defined as the 614 kHz measurement relative to 9.6 kHz. A 3 x 3 pixel region of interest was centred at this point. The changes in impedance with frequency for this region of interest show good overall reproducibility between electrode applications for eight frequencies (95% limits of agreement +/- 28%). This reproducibility is improved (95% limits of agreement +/- 13%) by omitting the highest frequency (1.2 MHz) which is most subject to system noise. The parameters for the Cole model derived from data with the highest frequency omitted are less reproducible between electrode applications (95% limits of agreement, R/S +/- 0.83, fc +/- 81.6, RC +/- 0.52, SC +/- 0.39). We suspect that the parametric model used may have an effect on this. The signals recorded at the highest frequency (1.2 MHz) are a major source of variability. The reproducibility results are improved by omitting this frequency from the analysis.

Entities:  

Mesh:

Year:  1996        PMID: 9001619     DOI: 10.1088/0967-3334/17/4a/025

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

Review 1.  Front-end architecture for a multi-frequency electrical impedance tomography system.

Authors:  D Jennings; I D Schneider
Journal:  Med Biol Eng Comput       Date:  2001-05       Impact factor: 2.602

2.  Regional distribution of blood volume within the preterm infant thorax during synchronised mechanical ventilation.

Authors:  Hazel R Carlisle; Ruth K Armstrong; Peter G Davis; Andreas Schibler; Inéz Frerichs; David G Tingay
Journal:  Intensive Care Med       Date:  2010-09-21       Impact factor: 17.440

3.  Reproducibility and repeatability of measuring the electrical impedance of the pregnant human cervix-the effect of probe size and applied pressure.

Authors:  Roobin P Jokhi; Vidita V Ghule; Brian H Brown; Dilly O C Anumba
Journal:  Biomed Eng Online       Date:  2009-06-17       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.