Literature DB >> 9001608

In vitro multifrequency electrical impedance measurements and modelling of the cervix in late pregnancy.

N J Avis1, S W Lindow, F Kleinermann.   

Abstract

Idiopathic preterm labour is the greatest single perinatal problem occurring in an unpredictable 6-8% of all pregnancies and accounting for 75% of all perinatal deaths. Preterm cervical softening is used clinically as an important indicator of cervical dysfunction but the subjective nature of present clinical assessment methods prevents reliable prediction of preterm labour. This paper reports the finding of a pilot investigation concerned with obtaining quantitative measurements of the in vitro electrical impedance of the cervix using a four-electrode multifrequency impedance measurement system. Impedance measurement obtained from six samples of cervical tissue taken from different subjects of caesarean section were fitted to the Cole equation and parameters derived to describe the ratio of extra- versus intracellular impedance and the characteristic frequency. Subjects at term display a lower extra- versus intracellular impedance ratio than the preterm subjects. This appears consistent with the expected increase in the hydration of the cervix approaching term and the resulting decrease in the extracellular impedance. Further studies are required to determine if multifrequency electrical impedance tomography could be used as a non-invasive screening test for preterm labour.

Entities:  

Mesh:

Year:  1996        PMID: 9001608     DOI: 10.1088/0967-3334/17/4a/014

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

1.  Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes.

Authors:  Saurabh V Gandhi; Dawn C Walker; Brian H Brown; Dilly O C Anumba
Journal:  Biomed Eng Online       Date:  2006-11-24       Impact factor: 2.819

2.  Reproducibility and repeatability of measuring the electrical impedance of the pregnant human cervix-the effect of probe size and applied pressure.

Authors:  Roobin P Jokhi; Vidita V Ghule; Brian H Brown; Dilly O C Anumba
Journal:  Biomed Eng Online       Date:  2009-06-17       Impact factor: 2.819

3.  Towards BirthAlert--A Clinical Device Intended for Early Preterm Birth Detection.

Authors:  Mozziyar Etemadi; Philip Chung; J Alex Heller; Jonathan A Liu; Larry Rand; Shuvo Roy
Journal:  IEEE Trans Biomed Eng       Date:  2013-07-23       Impact factor: 4.538

4.  The role of cervical Electrical Impedance Spectroscopy in the prediction of the course and outcome of induced labour.

Authors:  Roobin P Jokhi; Brian H Brown; Dilly O C Anumba
Journal:  BMC Pregnancy Childbirth       Date:  2009-09-02       Impact factor: 3.007

5.  A Preliminary Exploration of the Placental Position Influence on Uterine Electromyography Using Fractional Modelling.

Authors:  Müfit Şan; Arnaldo Batista; Sara Russo; Filipa Esgalhado; Catarina R Palma Dos Reis; Fátima Serrano; Manuel Ortigueira
Journal:  Sensors (Basel)       Date:  2022-02-22       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.