Literature DB >> 9001314

Evaluation of nasal prongs for estimating nasal flow.

J M Montserrat1, R Farré, E Ballester, M A Felez, M Pastó, D Navajas.   

Abstract

Nasal prongs (NP) connected to a pressure transducer have been suggested as a useful alternative for measuring nasal flow in sleep apnea/hypopnea patients. However, flow measured with NP is expected to be nonlinear. The aim of the present study was to analyze and correct the nonlinearity of nasal flow measurements with NP (VNP). Nasal flow was simultaneously measured with a pneumotachograph (PNT; V) and (NP; VNP) in six healthy subjects during 60 s of breathing at different tidal volumes. Nonlinearity of VNP was assessed by fitting separately, for inspiration and expiration, a Rorher-model equation (VNP x K1 x V + K2 x V2). In addition, we fitted the data to a simpler nonlinear quadratic model (P = K x V2). The main findings were: (1) an excellent fit of the Rorher equation to measured data in all cases; (2) although differences in the Rorher equation coefficients between inspiration and expiration were observed, they were not statistically significant; (3) a substantial intersubject variability was found; and finally, (4) the square root of VNP acceptably fitted the nasal flow data measured by PNT (V) in most cases. We conclude that in order to quantitatively assess nasal flow with NP, data should be corrected for their nonlinear pressure-flow relationships and, that the square root of the flow signal measured with NP is the simplest method of correcting for the observed nonlinearity.

Entities:  

Mesh:

Year:  1997        PMID: 9001314     DOI: 10.1164/ajrccm.155.1.9001314

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  21 in total

Review 1.  Pulse transit time: an appraisal of potential clinical applications.

Authors:  R P Smith; J Argod; J L Pépin; P A Lévy
Journal:  Thorax       Date:  1999-05       Impact factor: 9.139

Review 2.  Sleep . 3: Clinical presentation and diagnosis of the obstructive sleep apnoea hypopnoea syndrome.

Authors:  D Schlosshan; M W Elliott
Journal:  Thorax       Date:  2004-04       Impact factor: 9.139

3.  Inspiratory flow limitation in a normal population of adults in São Paulo, Brazil.

Authors:  Luciana O Palombini; Sergio Tufik; David M Rapoport; Indu A Ayappa; Christian Guilleminault; Luciana B M de Godoy; Laura S Castro; Lia Bittencourt
Journal:  Sleep       Date:  2013-11-01       Impact factor: 5.849

4.  An Official American Thoracic Society Workshop Report: Noninvasive Identification of Inspiratory Flow Limitation in Sleep Studies.

Authors:  Sushmita Pamidi; Susan Redline; David Rapoport; Indu Ayappa; Luciana Palombini; Ramon Farre; Jason Kirkness; Jean-Louis Pépin; Olli Polo; Andrew Wellman; R John Kimoff
Journal:  Ann Am Thorac Soc       Date:  2017-07

Review 5.  New Approaches to Diagnosing Sleep-Disordered Breathing.

Authors:  Scott A Sands; Robert L Owens; Atul Malhotra
Journal:  Sleep Med Clin       Date:  2016-03-04

6.  Relative prolongation of inspiratory time predicts high versus low resistance categorization of hypopneas.

Authors:  Anne M Mooney; Khader K Abounasr; David M Rapoport; Indu Ayappa
Journal:  J Clin Sleep Med       Date:  2012-04-15       Impact factor: 4.062

7.  Nasal pressure recording in the diagnosis of sleep apnoea hypopnoea syndrome.

Authors:  F Sériès; I Marc
Journal:  Thorax       Date:  1999-06       Impact factor: 9.139

8.  Polysomnographic determinants of nocturnal hypercapnia in patients with sleep apnea.

Authors:  Nattapong Jaimchariyatam; Raed A Dweik; Roop Kaw; Loutfi S Aboussouan
Journal:  J Clin Sleep Med       Date:  2013-03-15       Impact factor: 4.062

9.  Evaluation of a noninvasive algorithm for differentiation of obstructive and central hypopneas.

Authors:  Winfried J Randerath; Marcel Treml; Christina Priegnitz; Sven Stieglitz; Lars Hagmeyer; Christian Morgenstern
Journal:  Sleep       Date:  2013-03-01       Impact factor: 5.849

10.  The use of combined thermal/pressure polyvinylidene fluoride film airflow sensor in polysomnography.

Authors:  Meir Kryger; Todd Eiken; Li Qin
Journal:  Sleep Breath       Date:  2013-05-29       Impact factor: 2.816

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.