Literature DB >> 8996058

Thirty years experience with heart valve surgery: isolated aortic valve replacement.

J R Bessell1, G Gower, D R Craddock, J Stubberfield, G J Maddern.   

Abstract

BACKGROUND: Thirty years have elapsed since the commencement of open-heart surgery in South Australia. A retrospective study was performed to evaluate mortality and complication rates and to identify factors associated with poor outcomes in all patients who underwent prosthetic aortic valve replacement during this period.
METHODS: Questionnaires and personal contact have been used to generate a combined database of pre-operative and post-operative information and long-term follow-up on 1322 patients who underwent isolated prosthetic aortic valve replacement at the Cardio-Thoracic Surgical Unit of the Royal Adelaide Hospital between 1963 and 1992.
RESULTS: Complete survival follow-up data were obtained for 94% (1241) of the patients. The Bjork-Shiley valve was used in 66% (875) of the patients, a Starr-Edwards prosthesis in 31% (412), a St Jude prosthesis in 2% (26), and only 0.7% (9) bioprosthetic valves were inserted. The hospital mortality rate for the 30-year period was 2.9%. Progressively older and less fit patients have undergone surgery in recent years. The long-term survival of patients with aortic stenosis and aortic incompetence was not significantly different. Long-term survival was significantly shorter for patients with higher New York Heart Association (NYHA) functional classifications, and for patients in pre-operative atrial fibrillation. Pre-operative dyspnoea was significantly improved following aortic valve replacement. The rates of postoperative haemorrhagic and embolic complications were low by comparison with other published series.
CONCLUSIONS: Aortic valve replacement can be performed with low hospital mortality and complication rates, and significant symptomatic improvement can be expected. Aortic valve recipients have a favourable prognostic outcome compared with an age- and sex-matched population, and risk factors that determine long-term survival can be identified pre-operatively.

Entities:  

Mesh:

Year:  1996        PMID: 8996058     DOI: 10.1111/j.1445-2197.1996.tb00753.x

Source DB:  PubMed          Journal:  Aust N Z J Surg        ISSN: 0004-8682


  3 in total

Review 1.  Thirty-seven-year durability of a Starr-Edwards aortic prosthesis: case report and brief review of the literature.

Authors:  Mehmet Ozkokeli; Mehmet Ates; Abdurrahman Ekinci; Murat Akcar
Journal:  Tex Heart Inst J       Date:  2005

2.  Extended durability of a cloth-covered star-edwards caged ball prosthesis in aortic position.

Authors:  Yusuf Ata; Tamer Turk; Cüneyt Eris; Mihriban Yalcin; Filiz Ata; A Ozyazicioğlu
Journal:  Case Rep Med       Date:  2010-02-03

Review 3.  Bioprosthetic Aortic Valve Replacement in <50 Years Old Patients - Where is the Evidence?

Authors:  Amer Harky; Michael Man Yuen Suen; Chris Ho Ming Wong; Abdul Rahman Maaliki; Mohamad Bashir
Journal:  Braz J Cardiovasc Surg       Date:  2019-12-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.