Literature DB >> 8995746

Nitric oxide release in the peripheral blood during hemodialysis.

J Rysz1, M Luciak, J Kedziora, J Błaszczyk, E Sibińska.   

Abstract

These studies evaluated the nitric oxide (NO) release in peripheral blood during a four-hour hemodialysis (HD) with single-used cuprophane (CU), polysulfone (PS) and polyacrylonitrile (PAN) membranes in 10 chronic uremic patients. Continuous monitoring of blood NO concentrations was performed with a sterile NO sensor probe inserted vertically into the arterial blood line between the arteriovenous fistula and dialyzer. In the initial period of HD two peaks of blood NO concentrations were observed: the first occurred at the very start of HD and lasted approximately one minute, and the second peaked to a lesser extent at 20 to 26 minutes after the initiation of HD. The extent of NO release was dependent on the type of dialysis membrane used. Areas under curves for blood NO concentrations (in mumol x min) were as follows: CU, 450.8 +/- 163.3; PS, 247.3 +/- 150.6*; PAN, 200.4 +/- 91.0* (*P < 0.05 vs. CU). During the first hour of HD (N = 6) blood NO concentrations were significantly higher at the outlet of CU dialyzer than those found at the inlet. The areas under their curves (in mumol x min) were 169.1 +/- 1.9 and 107.5 +/- 1.6, respectively (P < 0.001). Areas under curves for blood NO concentrations measured for five minutes following a five-minute in vitro incubation of 5 ml heparinized uremic blood samples (N = 10) with dialysis membranes (50 cm2) were as follows (in nmol x min): CU, 2380 +/- 289*; PS, 1293 +/- 45*; PAN, 1117 +/- 37*; control, 502 +/- 56 (*P < 0.05 vs. control). The addition of sodium heparin to uremic blood platelet suspension induced an immediate rise in NO release in a dose-dependent manner, which proved to be a hyperbolic relationship. During HD with CU (N = 6), PS (N = 6) and PAN (N = 6) membranes blood plasma cGMP concentrations significantly increased, particularly at 20 and 60 minutes of the procedure. No significant differences in blood plasma cGMP levels were found between individual dialysis membranes, and no significant correlations were observed between blood plasma cGMP levels and blood NO concentrations. The results indicate that during HD NO is released in the peripheral blood due to blood-membrane and heparin-blood platelet interactions. The extent of intradialytic NO release is dependent on the type of dialysis membrane used (CU > PS approximately PAN).

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 8995746     DOI: 10.1038/ki.1997.36

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  4 in total

1.  eNOS Glu298Asp Polymorphism and Endothelial Dysfunction in Patients with and without End-stage Renal Disease.

Authors:  Nevin İlhan; Kadir Ateş; Necip İlhan; Dilara Kaman; Hüseyin Çeliker
Journal:  Balkan Med J       Date:  2016-03-01       Impact factor: 2.021

2.  Indices of activity of the nitric oxide system in hemodialysis patients.

Authors:  R J Schmidt; J Domico; L S Samsell; S Yokota; T S Tracy; M I Sorkin; K Engels; C Baylis
Journal:  Am J Kidney Dis       Date:  1999-08       Impact factor: 8.860

Review 3.  Dialysis headache.

Authors:  Ana Luisa de Lima Antoniazzi; Alexandre Pinto Corrado
Journal:  Curr Pain Headache Rep       Date:  2007-08

4.  Increased basal nitric oxide amplifies the association of inflammation with all-cause and cardiovascular mortality in prevalent hemodialysis patients.

Authors:  Ilia Beberashvili; Inna Sinuani; Ada Azar; Hadas Kadoshi; Gregory Shapiro; Leonid Feldman; Judith Sandbank; Zhan Averbukh
Journal:  Int Urol Nephrol       Date:  2013-04-10       Impact factor: 2.370

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.