Literature DB >> 8992917

Cost-effectiveness of implantable cardioverter defibrillators relative to amiodarone for prevention of sudden cardiac death.

D K Owens1, G D Sanders, R A Harris, K M McDonald, P A Heidenreich, A D Dembitzer, M A Hlatky.   

Abstract

BACKGROUND: Implantable cardioverter defibrillators (ICDs) are remarkably effective in terminating ventricular arrhythmias, but they are expensive and the extent to which they extend life is unknown. The marginal cost-effectiveness of ICDs relative to amiodarone has not been clearly established.
OBJECTIVE: To compare the cost-effectiveness of a third-generation implantable ICD with that of empirical amiodarone treatment for preventing sudden cardiac death in patients at high or intermediate risk.
DESIGN: A Markov model was used to evaluate health and economic outcomes of patients who received an ICD, amiodarone, or a sequential regimen that reserved ICD for patients who had an arrhythmia during amiodarone treatment. MEASUREMENTS: Life-years gained, quality-adjusted life-years gained, costs, and marginal cost-effectiveness.
RESULTS: For the base-case analysis, it was assumed that treatment with an ICD would reduce the total mortality rate by 20% to 40% at 1 year compared with amiodarone and that the ICD generator would be replaced every 4 years. In high-risk patients, if an ICD reduces total mortality by 20%, patients who receive an ICD live for 4.18 quality-adjusted life-years and have a lifetime expenditure of $88,400. Patients receiving amiodarone live for 3.68 quality-adjusted life-years and have a lifetime expenditure of $51,000. Marginal cost-effectiveness of an ICD relative to amiodarone is $74,400 per quality-adjusted life-year saved. If an ICD reduces mortality by 40%, the cost-effectiveness of ICD use is $37,300 per quality-adjusted life-year saved. Both choice of therapy (an ICD or amiodarone) and the cost-effectiveness ratio are sensitive to assumptions about quality of life.
CONCLUSIONS: Use of an ICD will cost more than $50,000 per quality-adjusted life-year gained unless it reduces all-cause mortality by 30% or more relative to amiodarone. Current evidence does not definitively support or exclude a benefit of this magnitude, but ongoing randomized trials have sufficient statistical power to do so.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 8992917     DOI: 10.7326/0003-4819-126-1-199701010-00001

Source DB:  PubMed          Journal:  Ann Intern Med        ISSN: 0003-4819            Impact factor:   25.391


  18 in total

Review 1.  [Public access defibrillation. Limited use by trained first responders and laymen].

Authors:  S Maisch; P Friederich; A E Goetz
Journal:  Anaesthesist       Date:  2006-12       Impact factor: 1.041

2.  Use of medical informatics to implement and develop clinical practice guidelines.

Authors:  D K Owens
Journal:  West J Med       Date:  1998-03

3.  Arrhythmia risk stratification based on QT interval instability: an intracardiac electrocardiogram study.

Authors:  Xiaozhong Chen; Larisa G Tereshchenko; Ronald D Berger; Natalia A Trayanova
Journal:  Heart Rhythm       Date:  2013-02-13       Impact factor: 6.343

4.  Cost-Effectiveness of Percutaneous Closure of the Left Atrial Appendage in Atrial Fibrillation Based on Results From PROTECT AF Versus PREVAIL.

Authors:  James V Freeman; David W Hutton; Geoffrey D Barnes; Ruo P Zhu; Douglas K Owens; Alan M Garber; Alan S Go; Mark A Hlatky; Paul A Heidenreich; Paul J Wang; Amin Al-Ahmad; Mintu P Turakhia
Journal:  Circ Arrhythm Electrophysiol       Date:  2016-06

5.  Are implantable cardioverter- defibrillators cost-effective?

Authors:  A M Naik; C T Peter
Journal:  Curr Cardiol Rep       Date:  2000-07       Impact factor: 2.931

Review 6.  Decision-analytic models to simulate health outcomes and costs in heart failure: a systematic review.

Authors:  Alexander Goehler; Benjamin P Geisler; Jennifer M Manne; Beate Jahn; Annette Conrads-Frank; Petra Schnell-Inderst; G Scott Gazelle; Uwe Siebert
Journal:  Pharmacoeconomics       Date:  2011-09       Impact factor: 4.981

7.  Economic evaluation of sirolimus-eluting stents.

Authors:  Fiona M Shrive; Braden J Manns; P Diane Galbraith; Merril L Knudtson; William A Ghali
Journal:  CMAJ       Date:  2005-02-01       Impact factor: 8.262

Review 8.  Cost effectiveness of implantable cardioverter defibrillator therapy versus drug therapy for patients at high risk of sudden cardiac death.

Authors:  Marian A Spath; Bernie J O'Brien
Journal:  Pharmacoeconomics       Date:  2002       Impact factor: 4.981

9.  A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [Role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ischemic eTiology in primary prevention treated with a biventricular ICD] study.

Authors:  Maurizio Gasparini; Carlo Menozzi; Alessandro Proclemer; Maurizio Landolina; Severio Iacopino; Angelo Carboni; Ernesto Lombardo; François Regoli; Mauro Biffi; Valeria Burrone; Alessandra Denaro; Giuseppe Boriani
Journal:  Eur Heart J       Date:  2009-06-29       Impact factor: 29.983

10.  Cost-effectiveness of implementing low-tidal volume ventilation in patients with acute lung injury.

Authors:  Colin R Cooke; Jeremy M Kahn; Timothy R Watkins; Leonard D Hudson; Gordon D Rubenfeld
Journal:  Chest       Date:  2009-03-24       Impact factor: 9.410

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.