Literature DB >> 8992210

Intensity correction of phased-array surface coil images.

J W Murakami1, C E Hayes, E Weinberger.   

Abstract

Phased-array coils distribute the high signal-to-noise ratio (SNR) performance of their small component surface coils over the larger area covered by the entire array. The inhomogeneous sensitivity profiles of the component surface coils result in images with very high signal near the phased-array and decreased signal far from the array. This paper presents a postprocessing algorithm for correcting these coil-related intensity variations. The algorithm's performance was evaluated by correcting images of volunteers acquired with several different receive-only phased-array surface coils.

Mesh:

Year:  1996        PMID: 8992210     DOI: 10.1002/mrm.1910350419

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction.

Authors:  Fa-Hsuan Lin; Ying-Jui Chen; John W Belliveau; Lawrence L Wald
Journal:  Hum Brain Mapp       Date:  2003-06       Impact factor: 5.038

2.  Multiple-profile homogeneous image combination: application to phase-cycled SSFP and multicoil imaging.

Authors:  Tolga Cukur; Michael Lustig; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

3.  Hybrid-Space SENSE Reconstruction for Simultaneous Multi-Slice MRI.

Authors:  Kangrong Zhu; Robert F Dougherty; Hua Wu; Matthew J Middione; Atsushi M Takahashi; Tao Zhang; John M Pauly; Adam B Kerr
Journal:  IEEE Trans Med Imaging       Date:  2016-02-18       Impact factor: 10.048

4.  AUTO-SMASH: a self-calibrating technique for SMASH imaging. SiMultaneous Acquisition of Spatial Harmonics.

Authors:  P M Jakob; M A Griswold; R R Edelman; D K Sodickson
Journal:  MAGMA       Date:  1998-11       Impact factor: 2.310

5.  Impact of baseline calibration on semiquantitative assessment of myocardial perfusion reserve by adenosine stress MRI.

Authors:  Andreas Seitz; Giancarlo Pirozzolo; Udo Sechtem; Raffi Bekeredjian; Peter Ong; Heiko Mahrholdt
Journal:  Int J Cardiovasc Imaging       Date:  2019-11-14       Impact factor: 2.357

6.  A parallel imaging approach to wide-field MR microscopy.

Authors:  Mary Preston McDougall; Steven M Wright
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

7.  Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement.

Authors:  Peter Kellman; Andrew E Arai; Elliot R McVeigh; Anthony H Aletras
Journal:  Magn Reson Med       Date:  2002-02       Impact factor: 4.668

8.  A subspace-based coil combination method for phased-array magnetic resonance imaging.

Authors:  Derya Gol Gungor; Lee C Potter
Journal:  Magn Reson Med       Date:  2015-03-13       Impact factor: 4.668

9.  Quantification of absolute fat mass using an adipose tissue reference signal model.

Authors:  Houchun H Hu; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2008-12       Impact factor: 4.813

10.  Compressed-sensing multispectral imaging of the postoperative spine.

Authors:  Pauline W Worters; Kyunghyun Sung; Kathryn J Stevens; Kevin M Koch; Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2012-07-12       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.