[Addition of ethanol to the distension medium in surgical hysteroscopy as screening to prevent "fluid overload". A prospective randomized comparative study of ablative versus non-ablative surgical hysteroscopy and different ethanol concentration].

D Wallwiener1, B Aydeniz, S Rimbach, A Fischer, R Conradi, G Bastert.   

Abstract

For answering the question at which hysteroscopical procedures an intraoperative screening method is necessary to avoid a fluid overload and whether a beginning fluid absorption can be diagnosed early by adding ethanol to the distension medium, a prospectively randomised comparative study of ablative versus non-ablative operative hysteroscopy with differing ethanol concentrations was performed (n = 120). Purisole (a mannit/sorbit solution) was used a distension medium. The measuring parameters (breath alcohol, amount of absorbed fluid, haematocrit and haemoglobin values, central venous pressure, heart frequency) were intraoperatively determined at 5-minute intervals. The results of the study show that with those hysteroscopical procedures during which the endometrium is not or only minimally injured (e.g. syneciolysis, hysteroscopic proximal tubal catheterisation). Intraoperative screening is not necessary due to the low absorbing amounts. With hysteroscopical procedures such as resection of myoma, endometrium ablation and septum resection, however, an addition of ethanol of 2% to the distension medium has proved useful, because with this method absorption amounts of 400 ml and more can be detected by positive values of breath alcohol. As the result of a further absorption of fluid, delayed in time compared to the first positive value of breath alcohol, there is an increase in central venous pressure and hyponatraemia. Intraoperative ethanol monitoring is a non-invasive procedure which can be performed during ablative-operative hysteroscopies and has no negative influence on the course of the intervention and the general condition of the patients.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8991843     DOI: 10.1055/s-2007-1022288

Source DB:  PubMed          Journal:  Geburtshilfe Frauenheilkd        ISSN: 0016-5751            Impact factor:   2.915


  2 in total

1.  Evaluation of the HystSim™-virtual reality trainer: an essential additional tool to train hysteroscopic skills outside the operation theater.

Authors:  Felix Neis; Sara Brucker; Melanie Henes; F Andrei Taran; Sascha Hoffmann; Markus Wallwiener; Birgitt Schönfisch; Nicole Ziegler; Angelika Larbig; Rudy Leon De Wilde
Journal:  Surg Endosc       Date:  2016-03-09       Impact factor: 4.584

2.  [The gynecological TURP syndrome. Severe hyponatremia and pulmonary edema during hysteroscopy].

Authors:  G Serocki; R Hanss; M Bauer; J Scholz; B Bein
Journal:  Anaesthesist       Date:  2009-01       Impact factor: 1.041

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.