Literature DB >> 8987263

Measurement of volumetric flow with no angle correction using multiplanar pulsed Doppler ultrasound.

J K Poulsen1, W Y Kim.   

Abstract

In this paper we show that by scanning at points on the surface of a sphere that the normal angle correction used in pulsed Doppler flow measurements is no longer necessary. Thus, it is possible to measure three-dimensional (3-D) flow using multiplanar ultrasound even though we only get one-dimensional (1-D) velocity information from pulsed Doppler ultrasound. The technique handles the three basic problems in flow measurements using ultrasound Doppler: The variations of the cross-sectional area, the time dependent changes in the velocity field, and the dependency of the angle of insonation. The technique is tested in a flow phantom using different angles of insonation to validate the angle independence of this new technique. Using six different angles of insonation in the range 0 degree to 69 degrees with flowrates in the range of 0-170 ml/s a linear dependence was found to be: measured (color Doppler) = 0.98 real flow (reference) + 1.36 ml/s, with a 95% confidence interval of +/- 13.9 ml/s.

Mesh:

Year:  1996        PMID: 8987263     DOI: 10.1109/10.495278

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

1.  Three dimensional echocardiography documents haemodynamic improvement by biventricular pacing in patients with severe heart failure.

Authors:  W Y Kim; P Søgaard; P T Mortensen; H K Jensen; A K Pedersen; B O Kristensen ; H Egeblad
Journal:  Heart       Date:  2001-05       Impact factor: 5.994

2.  Partial Volume Effect and Correction for 3-D Color Flow Acquisition of Volumetric Blood Flow.

Authors:  Oliver D Kripfgans; Jonathan M Rubin; Stephen Z Pinter; James Jago; Ron Leichner; J Brian Fowlkes
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-08-09       Impact factor: 2.725

3.  Three-dimensional US for Quantification of Volumetric Blood Flow: Multisite Multisystem Results from within the Quantitative Imaging Biomarkers Alliance.

Authors:  Oliver D Kripfgans; Stephen Z Pinter; Cristel Baiu; Matthew F Bruce; Paul L Carson; Shigao Chen; Todd N Erpelding; Jing Gao; Mark E Lockhart; Andy Milkowski; Nancy Obuchowski; Michelle L Robbin; Jonathan M Rubin; James A Zagzebski; J Brian Fowlkes
Journal:  Radiology       Date:  2020-06-30       Impact factor: 11.105

4.  Comparison of Variations Between Spectral Doppler and Gaussian Surface Integration Methods for Umbilical Vein Blood Volume Flow.

Authors:  Jonathan M Rubin; Sibo Li; J Brian Fowlkes; Shriram Sethuraman; Oliver D Kripfgans; William Shi; Marjorie C Treadwell; James R Jago; Ronald D Leichner; Stephen Z Pinter
Journal:  J Ultrasound Med       Date:  2020-08-07       Impact factor: 2.153

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.