Literature DB >> 8983585

Concordance and precision of dual X-ray absorptiometry with a 10 s scan.

R Patel1, M Seah, G M Blake, A L Jefferies, F M Crane, I Fogelman.   

Abstract

Development of dual energy X-ray absorptiometry (DXA) scanners with multidetector array technology has resulted in greatly shortened scanning times. The Hologic QDR-4500 includes an ultrafast (10 s) "turbo" scan mode recommended by the manufacturer for fast screening studies or as an aid to positioning the patient prior to scanning using the normal fast (30 s), medium (1 min) or high definition (2 min) modes. The suitability of the turbo mode for use in routine clinical studies was assessed by examining the concordance of bone mineral density (BMD) measurements obtained in this mode with measurements obtained using the three normal scanning modes. Studies in 151 female patients showed statistically significant discrepancies in four out of the six scan sites studied with systematic differences of 2.9% and 3.1% being observed for the posteroanterior (PA) spine and intertrochanteric region of the hip, respectively. In vivo precision for the 10 s scan found by performing duplicate measurements on 37 patients had a coefficient of variation of 1.3% for PA spine and 2.5% for femoral neck BMD. An investigation of the dependence of precision on body mass index (BMI) shows that the precision of spine and hip BMD was adversely affected with increasing BMI but the trend was statistically significant only in the spine. It was concluded that turbo mode scans are acceptable for routine clinical studies of the spine and hip but should not be used for longitudinal studies or patients with BMI greater than 30 kg m-2.

Entities:  

Mesh:

Year:  1996        PMID: 8983585     DOI: 10.1259/0007-1285-69-825-816

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  2 in total

1.  Prevalence and Risk Factors of Discordance Between Hip and Spinal Bone Mineral Density Among Saudi Subjects.

Authors:  Homoud Al Zaid; Muhannad S Alamri; Abdulhadi A AlOfair; Faisal S Alqusaiyer; Adel I Alorainey; Mohammad I Alasqah; Riad A Sulimani
Journal:  Cureus       Date:  2022-08-04

2.  Discordant effect of body mass index on bone mineral density and speed of sound.

Authors:  Miriam Steinschneider; Philippe Hagag; Micha J Rapoport; Mordechai Weiss
Journal:  BMC Musculoskelet Disord       Date:  2003-07-16       Impact factor: 2.362

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.