Calibration verification of the International Normalized Ratio.

G C Critchfield1, S T Bennett, W R Swaim.   

Abstract

The International Normalized Ratio (INR) system for reporting the prothrombin time (PT) is essentially a calibration activity intended to standardize PT reporting across various reagent/instrument systems. However, complete standardization of PT reporting through the INR has been difficult to achieve for a variety of reasons, including inaccurate assignment of thromboplastin International Sensitivity Indexes (ISIs) and specific (local) reagent/instrument effects. Until now, the individual laboratory has not been able to easily verify the accuracy of its INR. Using standard lyophilized plasmas with INR values assigned against IRP RBT/90 rabbit thromboplastin, the authors present a method that allows a laboratory to locally verify its range of accuracy for the INR. The method is illustrated on a single coagulometer with two thromboplastin lots of differing sensitivity (Pacific Hemostasis Thromboplastin-DS and Thromboplastin-D from rabbit sources, with respective International Sensitivity Indexes of 1.20 and 1.97). In this illustration of the method, the accuracy of Thromboplastin-DS was superior to that of Thromboplastin-D. Interpretation of the data and cautions regarding the use of standard plasmas for calibration verification are discussed. Using this method, a reportable range of accuracy at a given error tolerance can be established locally for INR measurements within a laboratory. Laboratories of any size can apply this method to study the accuracy of their INR reagent/instrument systems, thus performing calibration verification. When used in conjunction with assessments of assay precision, this method can help laboratories to select better reagent/instrument systems and thereby produce more accurate and more clinically meaningful INR results.

Entities:  

Mesh:

Year:  1996        PMID: 8980356     DOI: 10.1093/ajcp/106.6.786

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  2 in total

Review 1.  Clinical utilization of the international normalized ratio (INR).

Authors:  R S Riley; D Rowe; L M Fisher
Journal:  J Clin Lab Anal       Date:  2000       Impact factor: 2.352

2.  A primary care evaluation of three near patient coagulometers.

Authors:  E T Murray; D A Fitzmaurice; T F Allan; F D Hobbs
Journal:  J Clin Pathol       Date:  1999-11       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.