Literature DB >> 8975445

[Promoting venous return in plaster cast by AV impulse system. A preclinical study].

C Bulitta1, H J Kock, J Hanke, K W Sievers, K P Schmit-Neuerburg.   

Abstract

A new pneumatic compression pump--the AV-impulse system--causes increased return of venous blood from the lower limbs to the heart and increases total blood flow in the lower limbs by emptying the plantar venous plexus. Up to date there exist no experiences with using this system in plaster cast. We studied the maximum venous blood flow, the venous blood flow per minute and the venous diameters above the popliteal and femoral vein by duplexsonography in 12 lower limbs of 6 healthy persons before and after applying below-the-knee plaster casts. After applying the plaster cast we observed a slight increase in venous diameter (p = 0.02). By using the AV-impulse-system we observed a significant increase in maximum venous blood flow and venous blood flow per minute (p < 0.05). We demonstrated a significant increase of venous blood return in the deep veins of the lower limbs after applying a lower limb plaster cast by using the AV-impulse-system. These results indicate the possible benefit of using the AV-impulse-system as a physical method of thromboprophylaxis in orthopaedic and trauma patients with plaster cast immobilisation of the leg.

Entities:  

Mesh:

Year:  1996        PMID: 8975445

Source DB:  PubMed          Journal:  Unfallchirurgie        ISSN: 0340-2649


  18 in total

1.  [Changes in the perioperative venous hemodynamics and after immobilization of the lower extremity].

Authors:  F Bonnaire; T Brandt; J Raedecke; E H Kuner
Journal:  Unfallchirurg       Date:  1995-03       Impact factor: 1.000

Review 2.  Deep-vein thrombosis.

Authors:  E E Weinmann; E W Salzman
Journal:  N Engl J Med       Date:  1994-12-15       Impact factor: 91.245

3.  The effectiveness of intermittent plantar venous compression in prevention of deep venous thrombosis after total hip arthroplasty.

Authors:  J G Bradley; G H Krugener; H J Jager
Journal:  J Arthroplasty       Date:  1993-02       Impact factor: 4.757

4.  [Flow time analysis in sonographic flow measurements: an in vitro measurement for testing their accuracy].

Authors:  H Riediger; K W Sievers; E Löhr
Journal:  Rofo       Date:  1994-04

5.  [Mechanical dynamic ankle passive motion for physical prevention of thrombosis? Changes in hemodynamics in the lower pressure system with new dynamic splints].

Authors:  F Bonnaire; T Brandt; J Raedecke; A Bonk
Journal:  Unfallchirurg       Date:  1994-07       Impact factor: 1.000

6.  Reduction of post-traumatic swelling and compartment pressure by impulse compression of the foot.

Authors:  A M Gardner; R H Fox; C Lawrence; T D Bunker; R S Ling; A G MacEachern
Journal:  J Bone Joint Surg Br       Date:  1990-09

Review 7.  [The advantages and disadvantages of surgical prevention of thrombosis].

Authors:  H Straub
Journal:  Aktuelle Traumatol       Date:  1989-02

8.  [Thrombosis prevention in outpatients with lower limb injuries].

Authors:  P Kujath; U Spannagel; W Habscheid; G Schindler; A Weckbach
Journal:  Dtsch Med Wochenschr       Date:  1992-01-03       Impact factor: 0.628

9.  Prevention of deep vein thrombosis with low molecular-weight heparin in patients undergoing total hip replacement. A randomized trial. The German Hip Arthroplasty Trial (GHAT) Group.

Authors: 
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

10.  [Physical prevention of thrombosis with the ankle joint with the motorized ankle joint movement device. Initial results of a clinical study].

Authors:  C Chylarecki; G Hierholzer; G Rudofsky
Journal:  Unfallchirurgie       Date:  1995-06
View more