| Literature DB >> 897341 |
J C Loo, I J McGilveray, N Jordan.
Abstract
Separation of the acid breakdown products from digoxin in serum was accomplished by high performance liquid chromatography (HPLC). The major, less cardioactive, product digoxigenin was quantitated by several different commercial antisera from digoxin radioimmunoassay (RIA) kits. When two normal subjects were given digoxigenin (0.5 mg) orally appreciable concentrations were detected by digoxin RIA kit. Administration of a digoxin (0.5 mg) solution to the same overnight-fasted recumbent volunteers resulted in digoxigenin detection (HPLC-RIA) in serum only in one subject.Entities:
Mesh:
Substances:
Year: 1977 PMID: 897341
Source DB: PubMed Journal: Res Commun Chem Pathol Pharmacol ISSN: 0034-5164