Literature DB >> 8972324

Determination of glomerular filtration rate with Visipaque in patients with severely reduced renal function.

P Kjaersgaard1, J A Jakobsen, J O Nossen, K J Berg.   

Abstract

Iodixanol (Visipaque, Nycomed Imaging AS, Oslo, Norway), and isotonic, dimeric and non-ionic contrast medium (CM), and iohexol (Omnipaque, Nycomed Imaging AS, Oslo, Norway), a low-osmolar, monomeric and non-ionic contrast medium, were used as glomerular filtration rate (GFR) markers in patients with severely impaired renal function. Different methods for determining GFR were compared. A total of 16 patients with s-creatinine > 400 mumol/l were enrolled in the study; 8 in each CM group. Serum-iodine was measured, and plasma CM clearance was determined using the Bröchner-Mortensen method, the single-sample method and conventional method. The ratios between the results obtained from the conventional method and each of the two other methods were calculated. These data were plotted against the mean of the pairs compared, and the upper and lower limits of agreement were calculated as the mean ratio +/- 2SD. The comparison showed a high degree of agreement between methods, and the two simpler methods seem to be good alternatives to the conventional method, which gave good estimates of GFR (vs that determined by means of renal 125I-iothalamate clearance) when 24-h blood samples were included. However, slight overestimations of GFR, due to extrarenal excretion of the CM, were observed. In summary, serum clearance of iodixanol, as determined by the Bröchner-Mortensen method or single-sample method seems to be a simple and accurate marker for GFR in patients with severely reduced renal function. The findings obtained with iodixanol were similar to those obtained with iohexol.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8972324     DOI: 10.1007/bf00240692

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  20 in total

1.  A formula to estimate the approximate surface area if height and weight be known. 1916.

Authors:  D Du Bois; E F Du Bois
Journal:  Nutrition       Date:  1989 Sep-Oct       Impact factor: 4.008

2.  Endogenous creatinine clearance and serum creatinine in the clinical assessment of kidney function.

Authors:  A Rapoport; H Husdan
Journal:  Can Med Assoc J       Date:  1968-07-27       Impact factor: 8.262

3.  Glomerular filtration rate estimated after multiple injections of contrast medium during angiography.

Authors:  M Boijsen; G Granerus; L Jacobsson; L Björneld; M Aurell; U Tylén
Journal:  Acta Radiol       Date:  1988 Nov-Dec       Impact factor: 1.990

4.  A simple method for the determination of glomerular filtration rate.

Authors:  J Bröchner-Mortensen
Journal:  Scand J Clin Lab Invest       Date:  1972-11       Impact factor: 1.713

5.  The measurement of glomerular filtration rate in man with sodium iothalamate 131-I (Conray).

Authors:  E M Sigman; C M Elwood; F Knox
Journal:  J Nucl Med       Date:  1966-01       Impact factor: 10.057

6.  Utility of radioisotopic filtration markers in chronic renal insufficiency: simultaneous comparison of 125I-iothalamate, 169Yb-DTPA, 99mTc-DTPA, and inulin. The Modification of Diet in Renal Disease Study.

Authors:  R D Perrone; T I Steinman; G J Beck; C I Skibinski; H D Royal; M Lawlor; L G Hunsicker
Journal:  Am J Kidney Dis       Date:  1990-09       Impact factor: 8.860

7.  Chromium-51 ethylenediaminetetraacetate for estimation of globerular filtration rate.

Authors:  B D Stacy; G D Thorburn
Journal:  Science       Date:  1966-05-20       Impact factor: 47.728

8.  A method for the calculation of renal clearance based on a single plasma sample.

Authors:  L Jacobsson
Journal:  Clin Physiol       Date:  1983-08

9.  A single plasma sample method for estimation of the glomerular filtration rate in infants and children using iohexol, I: Establishment of a body weight-related formula for the distribution volume of iohexol.

Authors:  G Stake; T Monclair
Journal:  Scand J Clin Lab Invest       Date:  1991-06       Impact factor: 1.713

Review 10.  Main results of the first comparative clinical studies on Visipaque.

Authors:  B H Grynne; J O Nossen; B Bolstad; K W Borch
Journal:  Acta Radiol Suppl       Date:  1995
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.