Literature DB >> 8971947

Anticoagulation practices during neonatal extracorporeal membrane oxygenation: survey results.

D F Graves1, J M Chernin, M Kurusz, J B Zwischenberger.   

Abstract

To ascertain current anticoagulation management during neonatal extracorporeal membrane oxygenation (ECMO), a telephone survey was undertaken of all active ECMO (n = 81, 100% response rate) centres in the USA. Hospital policies regarding federal regulations governing laboratory tests [Clinical Laboratory Improvement Amendment (CLIA) 1988] were determined along with specific patient anticoagulation strategies and use of specific activated coagulation time (ACT) equipment. More than 90% of the respondents use the Hemochron device (International Technidyne Corp, Edison, NJ, USA) while the remaining centres use the Hemotec device (Medtronic Hemotec, Inc, Englewood, CO, USA). Quality control (QC) testing is performed by most centres, but there is no consensus regarding frequency of testing nor methods for dealing with abnormal results. Nearly one-half of the centres use beef lung-derived heparin and the other half use porcine intestinal-derived heparin. One-half of the programmes had a minimum heparin dose despite the ACT value, but the range varied significantly. Four out of five respondents reported that heparin dosages were dictated strictly by ACT results, and 63% will temporarily stop heparin administration for high ACT results, bleeding and/or surgery. Approximately one-third of the centres perform proficiency testing of the equipment in compliance with CLIA 1988. In conclusion, there appears to be no consensus regarding commitment to a QC programme among active ECMO centres.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8971947     DOI: 10.1177/026765919601100607

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  5 in total

Review 1.  Pharmacokinetic changes during extracorporeal membrane oxygenation: implications for drug therapy of neonates.

Authors:  Marcia L Buck
Journal:  Clin Pharmacokinet       Date:  2003       Impact factor: 6.447

2.  North American neonatal extracorporeal membrane oxygenation (ECMO) devices and team roles: 2008 survey results of Extracorporeal Life Support Organization (ELSO) centers.

Authors:  D Scott Lawson; Andrea F Lawson; Rich Walczak; Craig McRobb; Patty McDermott; Ian R Shearer; Andrew Lodge; James Jaggers
Journal:  J Extra Corpor Technol       Date:  2008-09

3.  Consumption of blood products during mechanical circulatory support in children: comparison between ECMO and a pulsatile ventricular assist device.

Authors:  Brigitte Stiller; Julia Lemmer; Frank Merkle; Vladimir Alexi-Meskishvili; Yuguo Weng; Michael Hübler; Andreas Koster; Thorsten Drews; Peter E Lange; Roland Hetzer
Journal:  Intensive Care Med       Date:  2004-07-22       Impact factor: 17.440

4.  Variability in anticoagulation management of patients on extracorporeal membrane oxygenation: an international survey.

Authors:  Melania M Bembea; Gail Annich; Peter Rycus; Gary Oldenburg; Ivor Berkowitz; Peter Pronovost
Journal:  Pediatr Crit Care Med       Date:  2013-02       Impact factor: 3.624

5.  Unfractionated heparin activity measured by anti-factor Xa levels is associated with the need for extracorporeal membrane oxygenation circuit/membrane oxygenator change: a retrospective pediatric study.

Authors:  Katherine Irby; Christopher Swearingen; Jonathan Byrnes; Joshua Bryant; Parthak Prodhan; Richard Fiser
Journal:  Pediatr Crit Care Med       Date:  2014-05       Impact factor: 3.624

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.