Use of simethicone as a patient preparation for abdominal sonography.

G Sommer, R A Filly, F C Laing.   

Abstract

Fifty-eight patients about to undergo abdominal ultrasonography were randomly assigned into groups receiving preparation with oral simethicone and into control groups. A percentage value of sound transmission through the abdomen was calculated for each patient using sonographic measurements taken from a series of prescribed scans by a sonographer unaware of the patient preparation employed. Results indicate a statistically significant improvement in through sound transmission for those groups receiving simethicone preparation.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 897173     DOI: 10.1148/125.1.219

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105