Literature DB >> 8970539

Pharmacokinetics and dosimetry of cobalt-55 and cobalt-57.

H M Jansen1, S Knollema, L V van der Duin, A T Willemsen, A Wiersma, E J Franssen, F G Russel, J Korf, A M Paans.   

Abstract

UNLABELLED: The isotopes 55Co and 57Co have been evaluated for PET and SPECT imaging in several clinical brain studies. For clinical application of cobalt, it is important to know the delivered radiation dose. The biodistribution of 55Co in both rat and humans after intravenous (bolus)-administration was studied. Based on pharmacokinetic data, radiation dose calculations according to the MIRD system are presented. By combining present measurements with literature data on 60CoCl2, the radiation dose delivered by 56CoCl2 (T1/2 78.8 days) and 57CoCl2 (T1/2 = 270 days) could be assessed.
METHODS: Whole-body Co-PET was performed in two healthy volunteers and one rat after intravenous injection of 37 and 3.7 MBq (1 resp. 0.1 mCi) 55Co, respectively. Blood samples were withdrawn during 300 min in humans. In seven rats the 55Co-biodistribution was determined by postmortem analysis. The residence time of the liver (critical organ) was determined in rats and humans. Blood partition-data of 55Co were assessed resulting in basic pharmacokinetic data in humans. Based on these kinetic data, radiation dose was calculated using the MIRD protocol.
RESULTS: In both the humans and the rat, the liver and bladder retained the highest fractions of 55Co (about 50% resp. 40% of the administered dose). The liver residence time in humans was 8.6 hr. The free fraction 55Co in the human plasma was at maximum 12%. The total-body mean transit time was 152 min. The volume of the central compartment = 2.8 liter and the steady-state distribution volume = 48 liter.
CONCLUSION: From these results, according to the WHO recommendations for class II studies, 22.2 MBq (0.6 mCi) 55Co and 14.8 MBq (0.4 mCi) 57Co (excluding any radionuclide contamination) can be used.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8970539

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  5 in total

1.  ARRONAX, a high-energy and high-intensity cyclotron for nuclear medicine.

Authors:  Ferid Haddad; Ludovic Ferrer; Arnaud Guertin; Thomas Carlier; Nathalie Michel; Jacques Barbet; Jean-François Chatal
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-05-09       Impact factor: 9.236

Review 2.  Mapping biological behaviors by application of longer-lived positron emitting radionuclides.

Authors:  Yang Zhou; Kwamena E Baidoo; Martin W Brechbiel
Journal:  Adv Drug Deliv Rev       Date:  2012-11-02       Impact factor: 15.470

3.  Cyclotron production and radiochemical separation of 55Co and 58mCo from 54Fe, 58Ni and 57Fe targets.

Authors:  H F Valdovinos; R Hernandez; S Graves; P A Ellison; T E Barnhart; C P Theuer; J W Engle; W Cai; R J Nickles
Journal:  Appl Radiat Isot       Date:  2017-09-06       Impact factor: 1.513

Review 4.  Non-invasive radionuclide imaging of trace metal trafficking in health and disease: "PET metallomics".

Authors:  George Firth; Julia E Blower; Joanna J Bartnicka; Aishwarya Mishra; Aidan M Michaels; Alex Rigby; Afnan Darwesh; Fahad Al-Salemee; Philip J Blower
Journal:  RSC Chem Biol       Date:  2022-04-11

5.  Yields of Photo-Proton Reactions on Nuclei of Nickel and Separation of Cobalt Isotopes from Irradiated Targets.

Authors:  Andrey G Kazakov; Julia S Babenya; Taisya Y Ekatova; Sergey S Belyshev; Vadim V Khankin; Alexander A Kuznetsov; Sergey E Vinokurov; Boris F Myasoedov
Journal:  Molecules       Date:  2022-02-24       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.