Literature DB >> 8970381

Glottic aperture and effective minute ventilation during nasal two-level positive pressure ventilation in spontaneous mode.

V F Parreira1, P Delguste, V Jounieaux, G Aubert, M Dury, D O Rodenstein.   

Abstract

Our goal was to verify glottic behavior and its effects on effective minute ventilation during intermittent positive pressure ventilation applied at increasing inspiratory pressure levels through a nasal mask (nIPPV) using a two-level positive pressure ventilator (two-level IPPV) in spontaneous mode. Ten subjects were studied while awake. The spontaneous mode was used at three levels of inspiratory positive airway pressure (IPAP): 10, 15, and 20 cm H2O. The expiratory pressure was kept at 4 cm H2O. Records of spontaneous breathing without nIPPV were also performed. The glottis was continuously monitored through a fiberoptic bronchoscope. We measured, breath by breath, the widest inspiratory angle formed by the vocal cords at the anterior commissure, the corresponding tidal volume (with respiratory inductive plethysmography), the respiratory frequency and other indices. Our data during wakefulness show that inspiratory pressures of 10 and 15 cm H2O did not result in increases in effective minute ventilation with respect to spontaneous breathing. Only at 20 cm H2O of IPAP did effective minute ventilation increase. This was due essentially to a decrease in respiratory frequency with increasing pressures, offsetting increases in tidal volume at 10 and 15, but not at 20 cm H2O of inspiratory pressure. Changes in end-tidal CO2 suggest that alveolar ventilation increased due to the change in breathing pattern. Contrary to what we observed previously with either two-level IPPV used in the controlled mode, or nIPPV performed with volumetric ventilators, the glottis did not play any noticeable role in the control of effective minute ventilation.

Entities:  

Mesh:

Year:  1996        PMID: 8970381     DOI: 10.1164/ajrccm.154.6.8970381

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  2 in total

1.  Assist-control ventilation vs. low levels of pressure support ventilation on sleep quality in intubated ICU patients.

Authors:  Bénédicte Toublanc; Dominique Rose; Jean-Charles Glérant; Géraldine Francois; Isabelle Mayeux; Daniel Rodenstein; Vincent Jounieaux
Journal:  Intensive Care Med       Date:  2007-05-11       Impact factor: 17.440

2.  Effects of non-invasive ventilation and posture on chest wall volumes and motion in patients with amyotrophic lateral sclerosis: a case series.

Authors:  Cristiana M Magalhães; Guilherme A Fregonezi; Mauro Vidigal-Lopes; Bruna S P P Vieira; Danielle S R Vieira; Verônica F Parreira
Journal:  Braz J Phys Ther       Date:  2016-06-16       Impact factor: 3.377

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.