Literature DB >> 8969388

Impact of pleurotomy, continuous positive airway pressure, and fluid balance during cardiopulmonary bypass on lung mechanics and oxygenation.

T B Gilbert1, G M Barnas, A J Sequeira.   

Abstract

OBJECTIVE: To determine effects of surgical pleurotomy, continuous positive airway pressure, and fluid balance during cardiopulmonary bypass (CPB) on lung mechanical properties and indices of oxygenation.
DESIGN: Prospective, descriptive, and interventional study.
SETTING: Cardiothoracic service at a major university referral center. PARTICIPANTS: Eighteen anesthetized-paralyzed patients undergoing elective coronary artery bypass grafting requiring CPB.
INTERVENTIONS: During CPB, continuous positive airway pressure (CPAP) was applied to nine patients, in nine others, no CPAP was applied.
MEASUREMENTS AND MAIN RESULTS: From measurements of airway and esophageal pressures and flow, lung resistance and elastance were determined before sternotomy and after sternal reapproximation. Measurements were made during forced ventilation over a physiologic range of tidal volumes and frequencies, and frequency and volume dependences of lung resistance and elastance were additionally identified. In all patients, lung resistance and elastance increased after CPB, consistent with models of pulmonary edema. Multiple regression analysis showed that these increases were relatively less in patients with intact pleurae (p < 0.05) or net negative fluid balance (p < 0.05); however, no difference in these increases was noted between patients receiving CPAP and those receiving no CPAP. Increases in lung resistance were positively correlated to net fluid balance, and negatively correlated to frequency and tidal volume (p < 0.05). Increases in lung elastance were positively correlated to tidal volume (p < 0.05). Absolute change in alveolar-arterial oxygen gradient was negatively correlated with net fluid balance, whereas percentage change was positively correlated to changes in lung elastance (p < 0.05).
CONCLUSIONS: These findings suggest that pleurotomy before CPB and positive fluid balance during CPB enhance postbypass pulmonary edema and/or atelectasis, as demonstrated by acute changes in respiratory mechanics and indices of oxygenation. Low levels of CPAP applied during CPB did not significantly change either mechanical properties or oxygenation.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8969388     DOI: 10.1016/s1053-0770(96)80043-7

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  4 in total

Review 1.  Pulmonary pathophysiology and lung mechanics in anesthesiology: a case-based overview.

Authors:  Marcos F Vidal Melo; Guido Musch; David W Kaczka
Journal:  Anesthesiol Clin       Date:  2012-09-01

2.  Early Open-Lung Ventilation Improves Clinical Outcomes in Patients with Left Cardiac Dysfunction Undergoing Off-Pump Coronary Artery Bypass: a Randomized Controlled Trial.

Authors:  Douglas W Bolzan; Walter José Gomes; Isadora S Rocco; Marcela Viceconte; Mara L S Nasrala; Hayanne O Pauletti; Rita Simone L Moreira; Nelson A Hossne; Ross Arena; Solange Guizilini
Journal:  Braz J Cardiovasc Surg       Date:  2016 Sep-Oct

3.  Pleural effusion post coronary artery bypass surgery: associations and complications.

Authors:  John D L Brookes; Michael Williams; Manish Mathew; Tristan Yan; Paul Bannon
Journal:  J Thorac Dis       Date:  2021-02       Impact factor: 2.895

4.  Effect of fluid balance on alveolar-arterial oxygen gradient in mechanically ventilated patients.

Authors:  Masoud Aliyali; Ali Sharifpour; Abdolrasol Tavakoli
Journal:  Tanaffos       Date:  2011
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.